Category: HPLC Tips and Suggestions
/
/
/
Add 10 micro molar EDTA or medronic acid to mobile phase for better peak shapes - Tips & Suggestions
Read More
Read More
Analyte retention decreases with mobile phase water content using the Cogent Bidentate C18 HPLC column has anything happened to the column - Tech Information
Read More
Read More
Analyze phosphorylated compounds with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Read More
Analyzing metformin in plasma samples how do I obtain reproducible results and peak shapes - FAQ
Read More
Read More
Aqueous Normal Phase ANP ballistic gradients compared to same in HILIC - Tips & Suggestions
Read More
Read More
Aqueous Normal Phase ANP defined & compared to Reversed Phase & Normal Phase definitions HPLC
Read More
Read More
Are there HPLC columns that could be used to separate both polar and nonpolar compounds in a single run - FAQ
Read More
Read More
Assuring retention of polar compounds in an Aqueous Normal Phase ANP gradient in positive ion mode LCMS - Tips & Suggestions
Read More
Read More
Avoid loss of concentration of heparin with HPLC when using syringe filters - Tips & Suggestions
Read More
Read More
Biological extracts Diamond Hydride columns and LCMS ion source diminished peak height problem - FAQ
Read More
Read More
Blocked HPLC column from proteins from the sample matrix can be recovered - Tips & Suggestions
Read More
Read More
Buffer concentration can affect ANP retention of acids in HPLC Analyses - Tips & Suggestions
Read More
Read More
Can amber or clear polypropylene vials be sterilized with autoclaving or ethylene oxide - FAQ
Read More
Read More
Can I choose HPLC mobile phase percentages other than those used in the HSQ Spreadsheet - FAQ
Read More
Read More
Can I use a silica or Silica-C guard column with an analytical column of a different phase - FAQ
Read More
Read More
Can I use phosphoric acid or sodium phosphate with the Cogent Diamond Hydride HPLC column - FAQ
Read More
Read More
Can I use the certified HPLC column supplied in the HSQ Kit for UHPLC performance qualification - FAQ
Read More
Read More
Can I use the Cogent Diamond Hydride column without mobile phase additives like formic acid - FAQ
Read More
Read More
Can I use the holmium oxide solution in a UV instrument that calls for Starna or NIST cuvettes - FAQ
Read More
Read More
Can I use trifluoroacetic acid TFA to improve the chromatographic performance in LCMS - FAQ
Read More
Read More
Can the HSQ or PQ qualification kits be used with Waters equipment and Empower chromatography data software - FAQ
Read More
Read More
Causes of high baseline noise with Cogent Diamond Hydride HPLC column - Tips & Suggestions
Read More
Read More
Citric acid retention and peak shape has changed compared to data from a previous run what happened - FAQ
Read More
Read More
Determining Efficiency of HPLC methods comparing 4um v 2.o HPLC columns - Tips & Suggestions
Read More
Read More
Difficulties with wavelength accuracy readings while performing a PQ of an HPLC - Tips & Suggestions
Read More
Read More
Eliminate broad split peaks in Aqueous Normal Phase ANP methods and a methanol diluent- Tips & Suggestions
Read More
Read More
Eliminating shoulder peaks in an HPLC method using Cogent RP C18 columns - Tips & Suggestions
Read More
Read More
For sugars analyzed by LCMS sodium acetate is recommended for sensitivity of Na adducts - Tips & Suggestions
Read More
Read More
For the separation of polar intermediates in reversed phase HPLC which C18 column do you recommend - FAQ
Read More
Read More
Ghost peaks appearing in results using a gradient with TFA which can degrade with time - Tips & Suggestions
Read More
Read More
Glucose pyruvate taurocholic acid gamma glutamylcysteine and other analysis - Tips & Suggestions
Read More
Read More
High molecular weight compounds that won't retain on Cogent Diamond Hydride column try Cogent Bidentate C8 300 - Tips & Suggestions
Read More
Read More
High pressure develops after flushing a Cogent Diamond Hydride column with acetonitrile cause and solution - FAQ
Read More
Read More
How can Cogent TYPE-C HPLC columns offer faster results compared to other type of silica based columns - FAQ
Read More
Read More
How can I fix poor peak shape for phosphorylated compounds in aqueous normal phase ANP methods - FAQ
Read More
Read More
How can I improve accuracy and precision when separating polar compounds by HPLC using Aqueous Normal Phase ANP - FAQ
Read More
Read More
How do I avoid distorted peak shapes when using a basic mobile phase pH for the analysis of a lipophilic amine - FAQ
Read More
Read More
How does ammonium fluoride affect HPLC and LCMS data if using Aqueous Normal Phase ANP methods - FAQ
Read More
Read More
How long will it take for chloroform to degrade the plastic safety coating on the mobile phase bottles if the bottle is broken during a fall - FAQ
Read More
Read More
How often do I need to do the conditioning procedure for a new Diamond Hydride column - FAQ
Read More
Read More
How similar fittings for chromatography can differ from different brands in HPLC - Tech Information
Read More
Read More
How tight should an autosampler vial cap be to prevent push through of the septa during injection - FAQ
Read More
Read More
How to calibrate UV-vis and HPLC detectors with NIST traceable solutions below 230nm - Tips & Suggestions
Read More
Read More
How to choose a suitable mobile phase additive for negative ionization mode LCMS - Tips & Suggestions
Read More
Read More
How to define custom plate measurements for the U-2D Micro-Sample Management System in the Waters Acquity console software - How to
Read More
Read More
How to determine concentration of an impurity in HPLC with the relative response factor RRF - How to
Read More
Read More
How to eliminate retention time drift in LCMS with Aqueous Normal Phase ANP methods - Tips & Suggestions
Read More
Read More
How to get improved retention and peak shape for glutamine glutamic acid and aspartic acid - Tips & Suggestions
Read More
Read More
How to handle sparging stones to avoid contamination of mobile phases - Tips & Suggestions
Read More
Read More
How to improve peak shapes, retention & carryover for polar compounds with the Cogent Diamond Hydride™ column - Tips & Suggestions
Read More
Read More
How to keep the Cogent Diamond Hydride column clean when using blood as a sample - Tips & Suggestions
Read More
Read More
How to prepare 10mM ammonium acetate buffer 90:10 in acetonitrile for HPLC and LCMS - Tips & Suggestions
Read More
Read More
How to prepare 16mM ammonium acetate buffer 90:10 in acetonitrile for HPLC - Tips & Suggestions
Read More
Read More
I am not observing any peaks for succinic acid or alpha-ketoglutarate with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Read More
I heard that there is not a good alternative to HILIC to achieve sufficient retention for some compounds - FAQ
Read More
Read More
I see a strange saw tooth type of pattern in the UV baseline using my Cogent HPLC column what is it and how can I fix it - FAQ
Read More
Read More
I see extra peaks in my chromatography when I am not using the same filter - Tips & Suggestions
Read More
Read More
Identify used U-2D inserts for multiple projects or in small sample sets - Tips & Suggestions
Read More
Read More
If an analyte is only soluble at basic pH can you use a basic mobile phase for my method - FAQ
Read More
Read More
Injection Technique for Aqueous Samples using Cogent TYPE-C Columns in ANP - Tips & Suggestions
Read More
Read More
Is TFA or formic acid better as an acidic mobile phase additive for Cogent TYPE-C columns - FAQ
Read More
Read More
Is there a difference in the properties of different colors of rubber in vial cap septa - FAQ
Read More
Read More
Issues arising from changes in mobile phase with acids to one with ammonium salts. Tips & Suggestions
Read More
Read More
LFER studies compared to Log D data in describing the Aqueous Normal Phase ANP retention - Tips & Suggestions
Read More
Read More
Lower retention is observed when functional group in a compound is ionized - Tips & Suggestions
Read More
Read More
Metal free stainless steel HPLC columns comparison to PEEK column performance - Tips & Suggestions
Read More
Read More
Mobile Phase recommendation Cogent Diamond Hydride columns for use with serum samples in Aqueous Normal Phase LCMS - Tips & Suggestions
Read More
Read More
Modify selectivity in an ANP method of HPLC using different mobile phase pH - Tips & Suggestions
Read More
Read More
My LCMS source was getting white film on it and at the same time the background noise was very low so is my Diamond Hydride column bleeding packing material - FAQ
Read More
Read More
My retention times are changing after storing my buffer and what could be causing this and tips to help avoid issues - FAQ
Read More
Read More
Peaks are broad and non symmetrical in LCMS method using Reversed Phase columns - Tips & Suggestions
Read More
Read More
Restoring the initial results with a method for analyzing AMP ADP ATP UDP and GPT in biological extracts - Tips & Suggestions
Read More
Read More
Retention and or peak shape for citric acid has changed compared to data from a previous HPLC run - Tips & Suggestions
Read More
Read More
Should I use methanol as the organic solvent in HPLC when using Aqueous Normal Phase ANP - FAQ
Read More
Read More
Silicone rubber in septa for autosampler vials vary in the way it is made - Tech Information
Read More
Read More
Since Cogent TYPE-C columns can be used in Reversed Phase or Normal Phase what do you suggest to switch these solvent systems which are not miscible - FAQ
Read More
Read More
Solving baseline problems in ANP methods with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Read More
Spurious peaks from nylon syringe filters with DI water using electrochemical detection can be avoided - Tips & Suggestions
Read More
Read More
Suggestion for separation of phenylephrine HCl acetaminophen and dextromethorphan - Tips & Suggestions
Read More
Read More
The best way to avoid with ion suppression issues in LCMS if you need to use an ion-pair agent - Primer
Read More
Read More
The effect of ionic strength of the mobile phase additive for HPLC columns in Aqueous Normal Phase - Tips & Suggestions
Read More
Read More
To obtain greater sensitivity than Na adducts for sugars could you add ammonia NH4 instead - FAQ
Read More
Read More
Troubleshooting problems with poor HPLC runs before the examining the column - Tips & Suggestions
Read More
Read More
Two gradients to use for analysis of hydrophilic and or hydrophobic molecules in the same Aqueous Normal Phase ANP method - Tips & Suggestions
Read More
Read More
Type of gradient to use for analysis of hydrophilic and hydrophobic molecules in the same HPLC or LCMS run - Tips & Suggestions
Read More
Read More
Use a low concentration of salt in your mobile phase to avoid ion suppression and build up on your inlet source - Tips & Suggestions
Read More
Read More
Using a Constant Pressure Method on two Instruments Producing Different Flow Rates- Tips & Suggestions
Read More
Read More
Using ammonium acetate or formate in an acetonitrile based HPLC mobile phase for Aqueous Normal Phase ANP - Tips & Suggestions
Read More
Read More
Using an Aqueous Normal Phase ANP method will sodium ions interfere with succinate when analyzing sodium succinate - FAQ
Read More
Read More
Using methanol instead of acetonitrile in an HPLC method should be done with caution - Tips & Suggestions
Read More
Read More
Using temperature changes for separations of terpenoids with the Cogent Bidentate C18 and UDC-Cholesterol HPLC columns - Tips & Suggestions
Read More
Read More
Using the wavelength calibration solution holmium oxide for HPLC UV detector performance qualification - Tips & Suggestions
Read More
Read More
Using triethylamine TEA in Aqueous Normal Phase ANP methods for simple sugars - Tips & Suggestions
Read More
Read More
Using two HPLC columns together in a tandem separation for polar and non polar retention - Tips & Suggestions
Read More
Read More
What are some common sources of variance during sample preparation in an analytical application - FAQ
Read More
Read More
What are some of the advantages of using Cogent TYPE-C prep and semi-prep HPLC columns - FAQ
Read More
Read More
What are the typical flow rates recommended by HPLC column companies to start with for various column ID - Primer
Read More
Read More
What can cause changing retention times and a peak showing up in my blank with a Silica-C column - FAQ
Read More
Read More
What effect does high injection volume have on column performance in Aqueous Normal Phase ANP HPLC- FAQ
Read More
Read More
What is the compatibility of Cogent TYPE-C Silica HPLC columns with UHPLC instruments - FAQ
Read More
Read More
What is the difference between precision point and conical point autosampler vial inserts - FAQ
Read More
Read More
What is the difference between related compounds and related substances in pharmaceutical HPLC - FAQ
Read More
Read More
What is the difference between weak and strong cation exchange for Ion Exchange columns - FAQ
Read More
Read More
What is the durability of the SOLVFIL when used with standard mobile phases and buffered mobile phases - FAQ
Read More
Read More
What is the effect of extra column volume for different HPLC instruments on the same method - FAQ
Read More
Read More
What is the maximum concentration of ammonium fluoride to use in a mobile phase to avoid column damage - Tips & Suggestions
Read More
Read More
What is the maximum loading capacity mass injection volume that can be used for a semi prep Cogent TYPE-C HPLC column - FAQ
Read More
Read More
What is the maximum salt concentration to use with Cogent TYPE-C HPLC columns with HPLC or LCMS - FAQ
Read More
Read More
What is the most effective way to clean HPLC columns after or before use - Tips & Suggestions
Read More
Read More
What is the pilot length or dimension X depth for end fittings uses to connect HPLC columns - FAQ
Read More
Read More
What is the purpose of using isopropanol IPA as part of the mobile phase solvent in ANP methods - FAQ
Read More
Read More
What problems can occur when using a dedicated Reversed Phase HPLC instrument for an Aqueous Normal Phase ANP method for the first time - FAQ
Read More
Read More
What special care should I take to protect my HPLC columns when I am equilibrating them - FAQ
Read More
Read More
What type of tubing do I use to connect the guard column holder to analytical columns - FAQ
Read More
Read More
What will the pressure be with a mobile phase of 90% methanol and 10% DI water with a 4.6 x 250mm Cogent TYPE-C HPLC column - FAQ
Read More
Read More
When I run gradients on my HPLC and switch from one gradient to another my baseline shows as negative and if I auto zero it becomes positive for the remainder of the run but when I start again it is negative - Primer
Read More
Read More
Which acid or base additive should I choose for positive or negative ion mode in LC-MS - FAQ
Read More
Read More
Which column do you suggest for Cocaine & metabolite Ecognin separation - Tips & Suggestions
Read More
Read More
Why am I observing broad split peaks in Aqueous Normal Phase ANP when using acetonitrile and methanol diluents - FAQ
Read More
Read More
Why are environmental conditions such as temperature relative humidity that are not specified on the CofA for the UV Calibration Kit - FAQ
Read More
Read More
Why are ionized polar compounds generally better retained in Aqueous Normal Phase ANP HPLC - FAQ
Read More
Read More
Why are pipettors not recommended for dispensing non aqueous liquids accurately and precisely - FAQ
Read More
Read More
Why do I see large intermittent pressure spikes in HPLC runs and can it be a defective column - FAQ
Read More
Read More
Why does the metal content of a silica particle contribute to the peak shape of my chromatogram in HPLC - FAQ
Read More
Read More
Why you should use temperature control with the UDC-Cholesterol column - Tips & Suggestions
Read More
Read More
Will a different guard column hardware system different from the Cogent system affect my results when using a Cogent column - FAQ
Read More
Read More
Will different guard columns packed by different column packers be equivalent - INTERNAL ONLY
Read More
Read More