Category: ARTICLES, APPNOTES, FAQ
/
Sub Categories
Acceptable wavelength band width for HPLC detectors when performing an HPLC Performance Qualification - Tech Information
Read More
Read More
Add 10 micro molar EDTA or medronic acid to mobile phase for better peak shapes - Tips & Suggestions
Read More
Read More
Analyte retention decreases with mobile phase water content using the Cogent Bidentate C18 HPLC column has anything happened to the column - Tech Information
Read More
Read More
Analyze phosphorylated compounds with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Read More
Analyzing metformin in plasma samples how do I obtain reproducible results and peak shapes - FAQ
Read More
Read More
Aqueous Normal Phase ANP ballistic gradients compared to same in HILIC - Tips & Suggestions
Read More
Read More
Aqueous Normal Phase ANP defined & compared to Reversed Phase & Normal Phase definitions HPLC
Read More
Read More
Are polypropylene screw top vials and caps free of metals sodium potassium magnesium and calcium - FAQ
Read More
Read More
Are polypropylene vials suited to avoiding adsorption issues with proteins compared to glass - FAQ
Read More
Read More
Are septa in autosampler vial caps self sealing inert and compatible with organic solvents - FAQ
Read More
Read More
Are the Chemical Solutions kits compliant with the latest USP-NF chapter revisions for 857 and 1857 - FAQ
Read More
Read More
Are the Cogent TYPE-C Silica based stationary phases available for sale as bulk materials - FAQ
Read More
Read More
Are the MicroSolv AQ brand of syringe filter membranes supported by extra membranes in the plastic housing - FAQ
Read More
Read More
Are there any solvents that I cannot use with the knitted reactor coils KRC and knitted delay tubes KDT - FAQ
Read More
Read More
Are there HPLC columns that could be used to separate both polar and nonpolar compounds in a single run - FAQ
Read More
Read More
Are there inherent problems with autosampler vials that have a filter built into the cap - FAQ
Read More
Read More
Assuring retention of polar compounds in an Aqueous Normal Phase ANP gradient in positive ion mode LCMS - Tips & Suggestions
Read More
Read More
Autosampler vials sold by MicroSolv will fit properly in your instruments - Tech Information
Read More
Read More
Avoid loss of concentration of heparin with HPLC when using syringe filters - Tips & Suggestions
Read More
Read More
Basic compound functional group dependent adsorption study in RSA autosampler vials - AppNote
Read More
Read More
Blocked HPLC column from proteins from the sample matrix can be recovered - Tips & Suggestions
Read More
Read More
Buffer concentration can affect ANP retention of acids in HPLC Analyses - Tips & Suggestions
Read More
Read More
Can amber or clear polypropylene vials be sterilized with autoclaving or ethylene oxide - FAQ
Read More
Read More
Can an autosampler needle pierce the Zone Free sealing film and will it reseal afterwards - FAQ
Read More
Read More
Can I choose HPLC mobile phase percentages other than those used in the HSQ Spreadsheet - FAQ
Read More
Read More
Can I expect a more predictable retention time with Silica-C columns than with ordinary silica - FAQ
Read More
Read More
Can I sterilize screw caps for autosampler vials that have silicone rubber with PTFE septa - FAQ
Read More
Read More
Can I use a PEEK finger tight fitting on stainless steel tubing - Can I use a SS fitting on PEEK tubing in HPLC - FAQ
Read More
Read More
Can I use a silica or Silica-C guard column with an analytical column of a different phase - FAQ
Read More
Read More
Can I use heat to remove the polyimide coating on Zero Flow capillaries without damaging the inner coating - FAQ
Read More
Read More
Can I use phosphoric acid or sodium phosphate with the Cogent Diamond Hydride HPLC column - FAQ
Read More
Read More
Can I use the certified HPLC column supplied in the HSQ Kit for UHPLC performance qualification - FAQ
Read More
Read More
Can I use the Cogent Diamond Hydride column without mobile phase additives like formic acid - FAQ
Read More
Read More
Can I use the holmium oxide solution in a UV instrument that calls for Starna or NIST cuvettes - FAQ
Read More
Read More
Can I use the MicroSolv Window Maker to remove polyimide from wires or solid core glass fiber - FAQ
Read More
Read More
Can I use trifluoroacetic acid TFA to improve the chromatographic performance in LCMS - FAQ
Read More
Read More
Can I use vial 95025-VN-05C with crimp cap 95025-08-1S in an oven at 105C for approximately 1 month - FAQ
Read More
Read More
Can the HSQ or PQ qualification kits be used with Waters equipment and Empower chromatography data software - FAQ
Read More
Read More
Can the MicoSolv Window Maker be used to remove the polyimide from the tips of capillaries - FAQ
Read More
Read More
Can the U-2D Micro-Sample management system be used in SPE manifold for 96-well plates - FAQ
Read More
Read More
Can the Window Maker heating modules be used with either US or European voltage units - FAQ
Read More
Read More
Causes of high baseline noise with Cogent Diamond Hydride HPLC column - Tips & Suggestions
Read More
Read More
Changing retention times of amino acids in biological extracts using ammonium acetate in HPLC methods. - Troubleshooting.
Read More
Read More
Citric acid retention and peak shape has changed compared to data from a previous run what happened - FAQ
Read More
Read More
Compatibility guidelines for safety coated mobile phase reservoir bottle use - Tips & Suggestions
Read More
Read More
Considerations for keeping gases dissolved in solution when using sparging stones - Tips & Suggestions
Read More
Read More
Could your PEEK tubing have contaminants via manufacturing processes from previous extrusion runs - FAQ
Read More
Read More
Determining Efficiency of HPLC methods comparing 4um v 2.o HPLC columns - Tips & Suggestions
Read More
Read More
Differences between the linearity solutions in the HSQ qualification kit - Tech Information
Read More
Read More
Difficulties with wavelength accuracy readings while performing a PQ of an HPLC - Tips & Suggestions
Read More
Read More
Direct silicon to carbon bonds on Cogent TYPE-C HPLC columns produce longer column lifetimes
Read More
Read More
Do Cogent TYPE-C Silica columns have a partial positive charge and if so is retention for basic compounds reduced because of this - Tech Information
Read More
Read More
Do different retention times for peaks in the Resolution Test Mixture on different systems impact the integrity of my data - FAQ
Read More
Read More
Do I need any special fittings to use the Cogent Column Filter with my current HPLC column - FAQ
Read More
Read More
Do Tanaka Plots for HPLC apply to columns used with Aqueous Normal Phase ANP methods - FAQ
Read More
Read More
Do the MicroSolv mobile phase delivery bottle caps have holes to insert tubing through - FAQ
Read More
Read More
Do you have suggestions for a knitted reactor coils KRC with a volume of 0.375ml with an internal diameter of 0.5mm - FAQ
Read More
Read More
Do you offer autosampler vials or caps for use with the Beckman PACE MDQ or other CE systems - FAQ
Read More
Read More
Does deactivation process of RSA-Pro X autosampler vials add any chlorides to the glass surface - FAQ
Read More
Read More
Does MicroSolv sell bared fused capillaries for CZE that are completely UV-transparent - FAQ
Read More
Read More
Does the Hichrom brand column coupler work with the Partisil and Partisphere HPLC columns - FAQ
Read More
Read More
Eliminating shoulder peaks in an HPLC method using Cogent RP C18 columns - Tips & Suggestions
Read More
Read More
For sugars analyzed by LCMS sodium acetate is recommended for sensitivity of Na adducts - Tips & Suggestions
Read More
Read More
For the separation of polar intermediates in reversed phase HPLC which C18 column do you recommend - FAQ
Read More
Read More
Ghost peaks appearing in results using a gradient with TFA which can degrade with time - Tips & Suggestions
Read More
Read More
High pressure develops after flushing a Cogent Diamond Hydride column with acetonitrile cause and solution - FAQ
Read More
Read More
How are your polypropylene vials and inserts for LCMS different from those of other manufacturers - FAQ
Read More
Read More
How can Cogent TYPE-C HPLC columns offer faster results compared to other type of silica based columns - FAQ
Read More
Read More
How can I fix poor peak shape for phosphorylated compounds in aqueous normal phase ANP methods - FAQ
Read More
Read More
How can I improve accuracy and precision when separating polar compounds by HPLC using Aqueous Normal Phase ANP - FAQ
Read More
Read More
How can I make changes to locked cells in the Excel spreadsheet that comes with the HSQ qualification kit - FAQ
Read More
Read More
How can I restore my Diamond Hydride HPLC column after I ran out of mobile phase and air was accidently introduced into it - FAQ
Read More
Read More
How do I avoid distorted peak shapes when using a basic mobile phase pH for the analysis of a lipophilic amine - FAQ
Read More
Read More
How do retention and efficiency of asymmetric dimethylarginine ADMA compare using 4um vs 2.o Diamond Hydride columns - AppNote
Read More
Read More
How do RSA autosampler vials compare against silanized vials for pharma applications - FAQ
Read More
Read More
How do the terms nano capillary and micro LC differ in terms of column ID and typical flow rates - FAQ
Read More
Read More
How does ammonium fluoride affect HPLC and LCMS data if using Aqueous Normal Phase ANP methods - FAQ
Read More
Read More
How does the shorter column supplied in the HSQ kit affect the data compared to the longer column from the PQ Kit - FAQ
Read More
Read More
How long will it take for chloroform to degrade the plastic safety coating on the mobile phase bottles if the bottle is broken during a fall - FAQ
Read More
Read More
How often do I need to do the conditioning procedure for a new Diamond Hydride column - FAQ
Read More
Read More
How similar fittings for chromatography can differ from different brands in HPLC - Tech Information
Read More
Read More
How tight should an autosampler vial cap be to prevent push through of the septa during injection - FAQ
Read More
Read More
How to choose a suitable mobile phase additive for negative ionization mode LCMS - Tips & Suggestions
Read More
Read More
How to define custom plate measurements for the U-2D Micro-Sample Management System in the Waters Acquity console software - How to
Read More
Read More
How to eliminate retention time drift in LCMS with Aqueous Normal Phase ANP methods - Tips & Suggestions
Read More
Read More
How to improve peak shapes, retention & carryover for polar compounds with the Cogent Diamond Hydride™ column - Tips & Suggestions
Read More
Read More
How to prepare 10mM ammonium acetate buffer 90:10 in acetonitrile for HPLC and LCMS - Tips & Suggestions
Read More
Read More
How to prepare 16mM ammonium acetate buffer 90:10 in acetonitrile for HPLC - Tips & Suggestions
Read More
Read More
I am not observing any peaks for succinic acid or alpha-ketoglutarate with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Read More
I currently use a glass filter why should I use the HSQ Kit solutions instead for qualification - FAQ
Read More
Read More
I see a strange saw tooth type of pattern in the UV baseline using my Cogent HPLC column what is it and how can I fix it - FAQ
Read More
Read More
Identify used U-2D inserts for multiple projects or in small sample sets - Tips & Suggestions
Read More
Read More
If an analyte is only soluble at basic pH can you use a basic mobile phase for my method - FAQ
Read More
Read More
If I use a buffer at pH 9 at 30 to 35C with the Zero Flow capillaries what lifetime should I expect from them - FAQ
Read More
Read More
In a cap that contains a butyl rubber with a PTFE septa which direction does the PTFE membrane face - FAQ
Read More
Read More
In order to prevent gas venting from an autosampler vial cap should I use snap or crimp or a screw cap - FAQ
Read More
Read More
Injection Technique for Aqueous Samples using Cogent TYPE-C Columns in ANP - Tips & Suggestions
Read More
Read More
Is the Excel template included in the Chemical Solutions Qualification kits CFR Part 21.11 compliant - FAQ
Read More
Read More
Is the Holmium Oxide Solution intended as a stand alone product or solely as a replacement solution for the HSQ Kit - FAQ
Read More
Read More
Is the power cable supplied with the MicroSolv Window Maker or is it a separate accessory - FAQ
Read More
Read More
Is the software for the MicroSolv HPLC PQ Kit supplied on CD or can it be downloaded - FAQ
Read More
Read More
Is there a difference in chromatography performance between clear and amber RSA vials - FAQ
Read More
Read More
Is there a difference in the properties of different colors of rubber in vial cap septa - FAQ
Read More
Read More
Is TYPE-C Silica a high purity support and have a low metal content silica like Type B silica - FAQ
Read More
Read More
Issues arising from changes in mobile phase with acids to one with ammonium salts. Tips & Suggestions
Read More
Read More
LFER studies compared to Log D data in describing the Aqueous Normal Phase ANP retention - Tips & Suggestions
Read More
Read More
Lower retention is observed when functional group in a compound is ionized - Tips & Suggestions
Read More
Read More
Mobile Phase recommendation Cogent Diamond Hydride columns for use with serum samples in Aqueous Normal Phase LCMS - Tips & Suggestions
Read More
Read More
Modify selectivity in an ANP method of HPLC using different mobile phase pH - Tips & Suggestions
Read More
Read More
My LCMS source was getting white film on it and at the same time the background noise was very low so is my Diamond Hydride column bleeding packing material - FAQ
Read More
Read More
My method uses an standard type-B silica based HPLC column is there a Cogent TYPE-C column equivalent substitute - FAQ
Read More
Read More
My retention times are changing after storing my buffer and what could be causing this and tips to help avoid issues - FAQ
Read More
Read More
Peaks are broad and non symmetrical in LCMS method using Reversed Phase columns - Tips & Suggestions
Read More
Read More
Polar and non polar peptides analyzed by LCMS with an Aqueous Normal Phase ANP method - Tips & Suggestions
Read More
Read More
Restoring the initial results with a method for analyzing AMP ADP ATP UDP and GPT in biological extracts - Tips & Suggestions
Read More
Read More
Should I use methanol as the organic solvent in HPLC when using Aqueous Normal Phase ANP - FAQ
Read More
Read More
Silicone rubber in septa for autosampler vials vary in the way it is made - Tech Information
Read More
Read More
Since Cogent TYPE-C columns can be used in Reversed Phase or Normal Phase what do you suggest to switch these solvent systems which are not miscible - FAQ
Read More
Read More
Solvents and solutions that should be avoided when using PEEK filters fittings or tubing - Tech Information
Read More
Read More
Solving baseline problems in ANP methods with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Read More
The best way to avoid with ion suppression issues in LCMS if you need to use an ion-pair agent - Primer
Read More
Read More
The differences in ion content between clear and amber borosilicate glass vials - Tech Information
Read More
Read More
The effect of ionic strength of the mobile phase additive for HPLC columns in Aqueous Normal Phase - Tips & Suggestions
Read More
Read More
To obtain greater sensitivity than Na adducts for sugars could you add ammonia NH4 instead - FAQ
Read More
Read More
Troubleshooting problems with poor HPLC runs before the examining the column - Tips & Suggestions
Read More
Read More
Tubing from Schoellerwerke is delivered in coils but is not referred to as 'coiled tube' - INTERNAL
Read More
Read More
Two gradients to use for analysis of hydrophilic and or hydrophobic molecules in the same Aqueous Normal Phase ANP method - Tips & Suggestions
Read More
Read More
Type of gradient to use for analysis of hydrophilic and hydrophobic molecules in the same HPLC or LCMS run - Tips & Suggestions
Read More
Read More
Understanding some of the differences between HILIC columns and TYPE-C columns - Tips & Suggestions
Read More
Read More
Use a low concentration of salt in your mobile phase to avoid ion suppression and build up on your inlet source - Tips & Suggestions
Read More
Read More
Using ammonium acetate or formate in an acetonitrile based HPLC mobile phase for Aqueous Normal Phase ANP - Tips & Suggestions
Read More
Read More
Using an Aqueous Normal Phase ANP method will sodium ions interfere with succinate when analyzing sodium succinate - FAQ
Read More
Read More
Using methanol instead of acetonitrile in an HPLC method should be done with caution - Tips & Suggestions
Read More
Read More
Using temperature changes for separations of terpenoids with the Cogent Bidentate C18 and UDC-Cholesterol HPLC columns - Tips & Suggestions
Read More
Read More
Using the wavelength calibration solution holmium oxide for HPLC UV detector performance qualification - Tips & Suggestions
Read More
Read More
Using triethylamine TEA in Aqueous Normal Phase ANP methods for simple sugars - Tips & Suggestions
Read More
Read More
Vials are listed as 12 x 32mm but my autosampler accepts a maximum diameter of 11.8mm will they fit - FAQ
Read More
Read More
Viscosity changes will affect these parameters in capillary electrophoresis - Tips & Suggestions
Read More
Read More
What are some common sources of variance during sample preparation in an analytical application - FAQ
Read More
Read More
What are some notable examples of journal articles that feature Aqueous Normal Phase ANP methods in metabolomics studies - FAQ
Read More
Read More
What are some of the advantages of using Cogent TYPE-C prep and semi-prep HPLC columns - FAQ
Read More
Read More
What are the differences between 33 and 51 expansion glass and which should I choose - FAQ
Read More
Read More
What are the main differences between Cogent Amide columns and other brands of Amide - FAQ
Read More
Read More
What are the size and materials of the mobile phase delivery bottle caps and O-rings - FAQ
Read More
Read More
What are the temperature specifications of the autosampler vial storage box and cap for 4ml vials - FAQ
Read More
Read More
What is the advantage or disadvantage of using Certified autosampler vials compared to MicroSolv vials - FAQ
Read More
Read More
What is the best way to attach the inlet of the knitted reactor coil KRC tubing to the outlet of a tee with a PEEK finger tight fitting that will hold high back pressure - FAQ
Read More
Read More
What is the chemical compatibility of the Chemical Resistant Sealing Mats for U-2D Micro-Sample Management System - FAQ
Read More
Read More
What is the chemical structure of the ligand in the Cogent DIOL HPLC stationary phase - FAQ
Read More
Read More
What is the compatibility of Cogent TYPE-C Silica HPLC columns with UHPLC instruments - FAQ
Read More
Read More
What is the difference between ferrules made of stainless steel vs stainless steel and PEEK hybrids - FAQ
Read More
Read More
What is the difference between related compounds and related substances in pharmaceutical HPLC - FAQ
Read More
Read More
What is the difference between the Beta Tools and other similar pliers on the market - FAQ
Read More
Read More
What is the difference between weak and strong cation exchange for Ion Exchange columns - FAQ
Read More
Read More
What is the durability of the SOLVFIL when used with standard mobile phases and buffered mobile phases - FAQ
Read More
Read More
What is the effect of extra column volume for different HPLC instruments on the same method - FAQ
Read More
Read More
What is the elution order for analytes in the Resolution Test Mixture supplied in the HSQ kit - Tech Information
Read More
Read More
What is the functional difference between the MRQ and the Max Recovery autosampler vials - FAQ
Read More
Read More
What is the highest amount of vacuum pressure that can be applied to the 47mm 0.45um nylon Filter Discs Membranes - FAQ
Read More
Read More
What is the inside diameter of the opening of your Luer Lock syringes catalog number 58901-S - FAQ
Read More
Read More
What is the internal diameter of the opening for 8mm crimp top BASIK brand autosampler vials - FAQ
Read More
Read More
What is the main difference between ordinary and LCMS compatible polypropylene vials - FAQ
Read More
Read More
What is the maximum concentration of ammonium fluoride to use in a mobile phase to avoid column damage - Tips & Suggestions
Read More
Read More
What is the maximum loading capacity mass injection volume that can be used for a semi prep Cogent TYPE-C HPLC column - FAQ
Read More
Read More
What is the maximum salt concentration to use with Cogent TYPE-C HPLC columns with HPLC or LCMS - FAQ
Read More
Read More
What is the most effective way to clean HPLC columns after or before use - Tips & Suggestions
Read More
Read More
What is the pH range of 316 stainless steel laboratory tubing fittings and sparging stones - FAQ
Read More
Read More
What is the purpose of the Resolution Test Mixture supplied in your Qualification Kits - FAQ
Read More
Read More
What is the purpose of using isopropanol IPA as part of the mobile phase solvent in ANP methods - FAQ
Read More
Read More
What is the recommended sparging stone pore size to use for carbonating applications - FAQ
Read More
Read More
What makes non-coated Mobile Phase Reservoir Bottles suitable for use in various temperature environments - FAQ
Read More
Read More
What maximum flow rate can I use for a PTFE 10m 0.75mm ID Knitted Reactor Coil KRC with isopropanol - FAQ
Read More
Read More
What precautions are used in the assembly of your vial and cap kits to prevent contamination - FAQ
Read More
Read More
What pressure should I expect with a Diamond Hydride 2.o HPLC column at flow rates from 0.2 to 2.0mL / min - FAQ
Read More
Read More
What special care should I take to protect my HPLC columns when I am equilibrating them - FAQ
Read More
Read More
What tubing is suitable for use in a knitted reactor coil KRC system utilizing isopropanol or concentrated HCl or concentrated NaOH or copper or luminol - FAQ
Read More
Read More
What type of tubing do I use to connect the guard column holder to analytical columns - FAQ
Read More
Read More
What will the pressure be with a mobile phase of 90% methanol and 10% DI water with a 4.6 x 250mm Cogent TYPE-C HPLC column - FAQ
Read More
Read More
When I run gradients on my HPLC and switch from one gradient to another my baseline shows as negative and if I auto zero it becomes positive for the remainder of the run but when I start again it is negative - Primer
Read More
Read More
Which acid or base additive should I choose for positive or negative ion mode in LC-MS - FAQ
Read More
Read More
Which Cogent TYPE-C column do you recommend for the separation of positional isomers by HPLC or LCMS - FAQ
Read More
Read More
Which column coupler do you recommend for pairing HPLC columns with guard columns- Tech Information
Read More
Read More
Which column do you suggest for Cocaine & metabolite Ecognin separation - Tips & Suggestions
Read More
Read More
Which crimp cap is most commonly used for residual solvent testing by the pharmaceutical industry - FAQ
Read More
Read More
Which crimp caps and septa are suitable for use with Solid Phase Micro Extraction SPME vials - FAQ
Read More
Read More
Which HPLC column ID dimensions are the Hichrom brand guard column holders cat no 82000-GH compatible with - FAQ
Read More
Read More
Which parameters can be determined with the supplied solutions in the MicroSolv PQ Excel template - FAQ
Read More
Read More
Which type of vial do you recommend to use with the U-2D Micro Sample Management inserts - FAQ
Read More
Read More
Why am I observing broad split peaks in Aqueous Normal Phase ANP when using acetonitrile and methanol diluents - FAQ
Read More
Read More
Why are environmental conditions such as temperature relative humidity that are not specified on the CofA for the UV Calibration Kit - FAQ
Read More
Read More
Why are the same size autosampler vials listed as 2mL 1.8mL or 1.5mL by different suppliers - FAQ
Read More
Read More
Why do I see large intermittent pressure spikes in HPLC runs and can it be a defective column - FAQ
Read More
Read More
Why does the metal content of a silica particle contribute to the peak shape of my chromatogram in HPLC - FAQ
Read More
Read More
Why use buffers during analysis and acid buffers such as the phosphoric acid for column storage solvents for Bidenate C18 columns? Will phosphate precipitate in the column INTERNAL ONLY
Read More
Read More
Why you should use temperature control with the UDC-Cholesterol column - Tips & Suggestions
Read More
Read More
Will I see any differences in my HPLC chromatography if I change to AQ syringe filters - FAQ
Read More
Read More
Working with ammonium acetate and LCMS requires attention to cleaning - Tips & Suggestions
Read More
Read More