Category: HPLC Suggestions and Information
/
/
Sub Categories
Acceptable wavelength band width for HPLC detectors when performing an HPLC Performance Qualification - Tech Information
Read More
Read More
Add 10 micro molar EDTA or medronic acid to mobile phase for better peak shapes - Tips & Suggestions
Read More
Read More
Analyte retention decreases with mobile phase water content using the Cogent Bidentate C18 HPLC column has anything happened to the column - Tech Information
Read More
Read More
Analyze phosphorylated compounds with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Read More
Aqueous Normal Phase ANP ballistic gradients compared to same in HILIC - Tips & Suggestions
Read More
Read More
Aqueous Normal Phase ANP defined & compared to Reversed Phase & Normal Phase definitions HPLC
Read More
Read More
Are there HPLC columns that could be used to separate both polar and nonpolar compounds in a single run - FAQ
Read More
Read More
Basic compound functional group dependent adsorption study in RSA autosampler vials - AppNote
Read More
Read More
Biological extracts Diamond Hydride columns and LCMS ion source diminished peak height problem - FAQ
Read More
Read More
Buffer concentration can affect ANP retention of acids in HPLC Analyses - Tips & Suggestions
Read More
Read More
Can I use the certified HPLC column supplied in the HSQ Kit for UHPLC performance qualification - FAQ
Read More
Read More
Can I use trifluoroacetic acid TFA to improve the chromatographic performance in LCMS - FAQ
Read More
Read More
Can the HSQ or PQ qualification kits be used with Waters equipment and Empower chromatography data software - FAQ
Read More
Read More
Can the U-2D Micro-Sample management system be used in SPE manifold for 96-well plates - FAQ
Read More
Read More
Compatibility guidelines for safety coated mobile phase reservoir bottle use - Tips & Suggestions
Read More
Read More
Difficulties with wavelength accuracy readings while performing a PQ of an HPLC - Tips & Suggestions
Read More
Read More
Do Tanaka Plots for HPLC apply to columns used with Aqueous Normal Phase ANP methods - FAQ
Read More
Read More
Do you have suggestions for a knitted reactor coils KRC with a volume of 0.375ml with an internal diameter of 0.5mm - FAQ
Read More
Read More
Does the UV-vis calibration kit operate in all three ranges UV and visible and visible/NIR - FAQ
Read More
Read More
Eliminate broad split peaks in Aqueous Normal Phase ANP methods and a methanol diluent- Tips & Suggestions
Read More
Read More
Eliminating shoulder peaks in an HPLC method using Cogent RP C18 columns - Tips & Suggestions
Read More
Read More
For the separation of polar intermediates in reversed phase HPLC which C18 column do you recommend - FAQ
Read More
Read More
Ghost peaks appearing in results using a gradient with TFA which can degrade with time - Tips & Suggestions
Read More
Read More
Glucose pyruvate taurocholic acid gamma glutamylcysteine and other analysis - Tips & Suggestions
Read More
Read More
High molecular weight compounds that won't retain on Cogent Diamond Hydride column try Cogent Bidentate C8 300 - Tips & Suggestions
Read More
Read More
How can Cogent TYPE-C HPLC columns offer faster results compared to other type of silica based columns - FAQ
Read More
Read More
How can I improve accuracy and precision when separating polar compounds by HPLC using Aqueous Normal Phase ANP - FAQ
Read More
Read More
How can I make changes to locked cells in the Excel spreadsheet that comes with the HSQ qualification kit - FAQ
Read More
Read More
How do I avoid distorted peak shapes when using a basic mobile phase pH for the analysis of a lipophilic amine - FAQ
Read More
Read More
How does ammonium fluoride affect HPLC and LCMS data if using Aqueous Normal Phase ANP methods - FAQ
Read More
Read More
How long will it take for chloroform to degrade the plastic safety coating on the mobile phase bottles if the bottle is broken during a fall - FAQ
Read More
Read More
How often do I need to do the conditioning procedure for a new Diamond Hydride column - FAQ
Read More
Read More
How tight should an autosampler vial cap be to prevent push through of the septa during injection - FAQ
Read More
Read More
How to calibrate UV-vis and HPLC detectors with NIST traceable solutions below 230nm - Tips & Suggestions
Read More
Read More
How to choose a suitable mobile phase additive for negative ionization mode LCMS - Tips & Suggestions
Read More
Read More
How to determine concentration of an impurity in HPLC with the relative response factor RRF - How to
Read More
Read More
How to get improved retention and peak shape for glutamine glutamic acid and aspartic acid - Tips & Suggestions
Read More
Read More
I heard that there is not a good alternative to HILIC to achieve sufficient retention for some compounds - FAQ
Read More
Read More
I see a strange saw tooth type of pattern in the UV baseline using my Cogent HPLC column what is it and how can I fix it - FAQ
Read More
Read More
I see extra peaks in my chromatography when I am not using the same filter - Tips & Suggestions
Read More
Read More
If an analyte is only soluble at basic pH can you use a basic mobile phase for my method - FAQ
Read More
Read More
Is the Excel template included in the Chemical Solutions Qualification kits CFR Part 21.11 compliant - FAQ
Read More
Read More
Is the software for the MicroSolv HPLC PQ Kit supplied on CD or can it be downloaded - FAQ
Read More
Read More
Is there a difference in chromatography performance between clear and amber RSA vials - FAQ
Read More
Read More
LFER studies compared to Log D data in describing the Aqueous Normal Phase ANP retention - Tips & Suggestions
Read More
Read More
Lower retention is observed when functional group in a compound is ionized - Tips & Suggestions
Read More
Read More
Mobile Phase recommendation Cogent Diamond Hydride columns for use with serum samples in Aqueous Normal Phase LCMS - Tips & Suggestions
Read More
Read More
My LCMS source was getting white film on it and at the same time the background noise was very low so is my Diamond Hydride column bleeding packing material - FAQ
Read More
Read More
My retention times are changing after storing my buffer and what could be causing this and tips to help avoid issues - FAQ
Read More
Read More
Polar and non polar peptides analyzed by LCMS with an Aqueous Normal Phase ANP method - Tips & Suggestions
Read More
Read More
Retention and or peak shape for citric acid has changed compared to data from a previous HPLC run - Tips & Suggestions
Read More
Read More
Should I use methanol as the organic solvent in HPLC when using Aqueous Normal Phase ANP - FAQ
Read More
Read More
Since Cogent TYPE-C columns can be used in Reversed Phase or Normal Phase what do you suggest to switch these solvent systems which are not miscible - FAQ
Read More
Read More
Since Cogent TYPE-C Silica columns use a transition metal catalyst in production what is the presence of any trace quantity on the surface of the stationary phase- FAQ
Read More
Read More
Spurious peaks from nylon syringe filters with DI water using electrochemical detection can be avoided - Tips & Suggestions
Read More
Read More
The differences in ion content between clear and amber borosilicate glass vials - Tech Information
Read More
Read More
The effect of ionic strength of the mobile phase additive for HPLC columns in Aqueous Normal Phase - Tips & Suggestions
Read More
Read More
To obtain greater sensitivity than Na adducts for sugars could you add ammonia NH4 instead - FAQ
Read More
Read More
Two gradients to use for analysis of hydrophilic and or hydrophobic molecules in the same Aqueous Normal Phase ANP method - Tips & Suggestions
Read More
Read More
Type of gradient to use for analysis of hydrophilic and hydrophobic molecules in the same HPLC or LCMS run - Tips & Suggestions
Read More
Read More
Understanding some of the differences between HILIC columns and TYPE-C columns - Tips & Suggestions
Read More
Read More
Use a low concentration of salt in your mobile phase to avoid ion suppression and build up on your inlet source - Tips & Suggestions
Read More
Read More
Using an Aqueous Normal Phase ANP method will sodium ions interfere with succinate when analyzing sodium succinate - FAQ
Read More
Read More
Using methanol instead of acetonitrile in an HPLC method should be done with caution - Tips & Suggestions
Read More
Read More
Using temperature changes for separations of terpenoids with the Cogent Bidentate C18 and UDC-Cholesterol HPLC columns - Tips & Suggestions
Read More
Read More
Using triethylamine TEA in Aqueous Normal Phase ANP methods for simple sugars - Tips & Suggestions
Read More
Read More
Using two HPLC columns together in a tandem separation for polar and non polar retention - Tips & Suggestions
Read More
Read More
What are some notable examples of journal articles that feature Aqueous Normal Phase ANP methods in metabolomics studies - FAQ
Read More
Read More
What are some of the advantages of using Cogent TYPE-C prep and semi-prep HPLC columns - FAQ
Read More
Read More
What are the differences between 33 and 51 expansion glass and which should I choose - FAQ
Read More
Read More
What can cause changing retention times and a peak showing up in my blank with a Silica-C column - FAQ
Read More
Read More
What effect does high injection volume have on column performance in Aqueous Normal Phase ANP HPLC- FAQ
Read More
Read More
What is the compatibility of Cogent TYPE-C Silica HPLC columns with UHPLC instruments - FAQ
Read More
Read More
What is the durability of the SOLVFIL when used with standard mobile phases and buffered mobile phases - FAQ
Read More
Read More
What is the effect of extra column volume for different HPLC instruments on the same method - FAQ
Read More
Read More
What is the elution order for analytes in the Resolution Test Mixture supplied in the HSQ kit - Tech Information
Read More
Read More
What is the maximum concentration of ammonium fluoride to use in a mobile phase to avoid column damage - Tips & Suggestions
Read More
Read More
What is the maximum loading capacity mass injection volume that can be used for a semi prep Cogent TYPE-C HPLC column - FAQ
Read More
Read More
What is the maximum salt concentration to use with Cogent TYPE-C HPLC columns with HPLC or LCMS - FAQ
Read More
Read More
What is the most effective way to clean HPLC columns after or before use - Tips & Suggestions
Read More
Read More
What is the pilot length or dimension X depth for end fittings uses to connect HPLC columns - FAQ
Read More
Read More
What is the purpose of the Resolution Test Mixture supplied in your Qualification Kits - FAQ
Read More
Read More
What is the purpose of using isopropanol IPA as part of the mobile phase solvent in ANP methods - FAQ
Read More
Read More
What problems can occur when using a dedicated Reversed Phase HPLC instrument for an Aqueous Normal Phase ANP method for the first time - FAQ
Read More
Read More
What type of tubing do I use to connect the guard column holder to analytical columns - FAQ
Read More
Read More
What will the pressure be with a mobile phase of 90% methanol and 10% DI water with a 4.6 x 250mm Cogent TYPE-C HPLC column - FAQ
Read More
Read More
When I run gradients on my HPLC and switch from one gradient to another my baseline shows as negative and if I auto zero it becomes positive for the remainder of the run but when I start again it is negative - Primer
Read More
Read More
Which parameters can be determined with the supplied solutions in the MicroSolv PQ Excel template - FAQ
Read More
Read More
Why am I observing broad split peaks in Aqueous Normal Phase ANP when using acetonitrile and methanol diluents - FAQ
Read More
Read More
Why are pipettors not recommended for dispensing non aqueous liquids accurately and precisely - FAQ
Read More
Read More
Why are the same size autosampler vials listed as 2mL 1.8mL or 1.5mL by different suppliers - FAQ
Read More
Read More
Why do I see large intermittent pressure spikes in HPLC runs and can it be a defective column - FAQ
Read More
Read More
Will a different guard column hardware system different from the Cogent system affect my results when using a Cogent column - FAQ
Read More
Read More
Will different guard columns packed by different column packers be equivalent - INTERNAL ONLY
Read More
Read More
Will I protect HPLC columns from samples that get permanently adsorbed to the column by using a syringe filter - FAQ
Read More
Read More