Category: HPLC Suggestions and Information
/
/
A white film developed on my MS source so is this column packing material - FAQ
Read More
Acceptable wavelength band width for HPLC detectors when performing an HPLC Performance Qualification - Tech Information
Read More
Achieve optimal seals when crimping caps on vials - How to
Read More
Add 10 micro molar EDTA or medronic acid to mobile phase for better peak shapes - Tips & Suggestions
Read More
Adjusted retention time hold up time - Primer
Read More
Adjusted retention time in HPLC - HPLC Primer
Read More
Adsorption can happen quickly in an autosampler vial - Tips & Suggestions
Read More
Advantages of using a 3.0mm ID HPLC column for LCMS - Tech Information
Read More
Analyte retention decreases with mobile phase water content using the Cogent Bidentate C18 HPLC column has anything happened to the column - Tech Information
Read More
Analyze phosphorylated compounds with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
AQ brand polypropylene MS vials compared to market leading plastic vials for LCMS - FAQ
Read More
Aqueous Normal Phase ANP and how can it is useful for polar compounds - Tech Information
Read More
Aqueous Normal Phase ANP ballistic gradients compared to same in HILIC - Tips & Suggestions
Read More
Aqueous Normal Phase ANP defined & compared to Reversed Phase & Normal Phase definitions HPLC
Read More
Aqueous Normal Phase ANP HPLC retention mechanism elucidated - Tech Information
Read More
Aqueous Normal Phase ANP HPLC what is it - FAQ
Read More
Aqueous Normal Phase ANP solvent strength order - FAQ
Read More
Are RSA vials suitable for elemental analysis - FAQ
Read More
Are the AQ Advanced Quality brand of LCMS vials compatible with DMSO - FAQ
Read More
Are the Chemical Solutions qualification solutions for HPLC NIST traceable - FAQ
Read More
Are there HPLC columns that could be used to separate both polar and nonpolar compounds in a single run - FAQ
Read More
Basic compound adsorption study with time dependence in vials - AppNote
Read More
Basic compound functional group dependent adsorption study in RSA autosampler vials - AppNote
Read More
Better methods than HILIC in HPLC and LCMS - Tips & Suggestions
Read More
Better separation of two peaks for Reversed Phase RP HPLC - Tips & Suggestions
Read More
Biological extracts Diamond Hydride columns and LCMS ion source diminished peak height problem - FAQ
Read More
Bubbling or fizzing coming from a new Cogent TYPE-C column - Tech Information
Read More
Buffer concentration can affect ANP retention of acids in HPLC Analyses - Tips & Suggestions
Read More
Calculate assay of lisinopril dihydrate based on the anhydrous form - How to
Read More
Calculating theoretical plates N at half height - How To
Read More
Can Aqueous Normal Phase ANP methods be used to separate steroids - FAQ
Read More
Can Cogent TYPE-C HPLC columns be used in supercritical fluid chromatography SFC - FAQ
Read More
Can I backflush the Cogent column filter for longer in-service life - FAQ
Read More
Can I make a PTFE syringe filter more hydrophilic - FAQ
Read More
Can I use benzene as a mobile phase solvent in HPLC - FAQ
Read More
Can I use the certified HPLC column supplied in the HSQ Kit for UHPLC performance qualification - FAQ
Read More
Can I use the UV-vis Calibration Kit to qualify detection at 200nm - FAQ
Read More
Can I use trifluoroacetic acid TFA to improve the chromatographic performance in LCMS - FAQ
Read More
Can the all silicone cap mats be sterilized - FAQ
Read More
Can the Cogent Column Filters replace my HPLC guard columns - FAQ
Read More
Can the HSQ Kit be used to measure the LOQ and LOD differences between instruments - FAQ
Read More
Can the HSQ or PQ qualification kits be used with Waters equipment and Empower chromatography data software - FAQ
Read More
Can the U-2D Micro-Sample management system be used in SPE manifold for 96-well plates - FAQ
Read More
Changing column ID means changing your gradient - Tips & Suggestions
Read More
Check for high pressure traced to the HPLC pump module - Tips & Suggestions
Read More
Choose an appropriate re-equilibration or post time for gradient HPLC - How To
Read More
Cogent Cyano RP and Cyano NP definitions - INTERNAL
Read More
Cogent silica hydride HPLC columns by order of hydrophobicity - Tips & Suggestions
Read More
Cogent TYPE-C column end fitting hardware and dimensions - Tips & Suggestions
Read More
Cogent TYPE-C columns used in prep chromatography offer value - Tips & Suggestions
Read More
Compatibility guidelines for safety coated mobile phase reservoir bottle use - Tips & Suggestions
Read More
Convert HPLC columns between Reversed Phase and Normal Phase - How to
Read More
Converting Cogent TYPE-C columns to normal phase after use in reversed phase - How To
Read More
Cut PEEK tubing using a Clean Cut90 cutter - How to
Read More
Cut stainless steel tubing for HPLC properly - How to
Read More
Cysteine analysis tips for LCMS - Tips & Suggestions
Read More
Determine dwell volume of gradient HPLC systems - How To
Read More
Determine the asymmetry factor in HPLC at 10 percent peak height - How To
Read More
Determining efficiency of HPLC methods 4um v 2um - FAQ
Read More
Determining HPLC method accuracy - How To
Read More
Determining the precision of an HPLC method - Tips & Suggestions
Read More
Determining wavelength accuracy below 230nm for HPLC instruments - How To
Read More
Developing a Bromhexine HPLC method - Tips & Suggestions
Read More
Difference between adsorption and absorption - FAQ
Read More
Difficulties with wavelength accuracy readings while performing a PQ of an HPLC - Tips & Suggestions
Read More
Do all PEEK HPLC fittings fit all receiving ports - FAQ
Read More
Do autosampler vials and caps have a temperature range - FAQ
Read More
Do Tanaka Plots for HPLC apply to columns used with Aqueous Normal Phase ANP methods - FAQ
Read More
Do the Cogent Silica-C columns contain any carbon - FAQ
Read More
Do you have suggestions for a knitted reactor coils KRC with a volume of 0.375ml with an internal diameter of 0.5mm - FAQ
Read More
Does the method used in the HSQ Kit for HPLC need to be validated - FAQ
Read More
Does the UV-vis calibration kit operate in all three ranges UV and visible and visible/NIR - FAQ
Read More
Dwell volume effect on HPLC analyte retention in gradient methods - Primer
Read More
Effect of diluent on analyte adsorption to glass autosampler vials - White Paper
Read More
Effects of washing and re-using autosampler vials on sample loss - Tech Information
Read More
Eliminate broad split peaks in Aqueous Normal Phase ANP methods and a methanol diluent- Tips & Suggestions
Read More
Eliminate high background noise using a new Cogent HPLC column - Tips & Suggestions
Read More
Eliminating shoulder peaks in an HPLC method using Cogent RP C18 columns - Tips & Suggestions
Read More
Establishing HPLC method linearity - Tips & Suggestions
Read More
Features and benefits of the U-2D Micro Sample Management System - Tech Information
Read More
For Normal Phase HPLC which syringe filter do you recommend - FAQ
Read More
For the separation of polar intermediates in reversed phase HPLC which C18 column do you recommend - FAQ
Read More
Fractions to decimals to metric chart - Tech Information
Read More
Ghost peaks appearing in results using a gradient with TFA which can degrade with time - Tips & Suggestions
Read More
Glucose pyruvate taurocholic acid gamma glutamylcysteine and other analysis - Tips & Suggestions
Read More
Has there been a risk assessment for the use of SOLVFil in GMP laboratories - FAQ
Read More
Headspace septa temperature performance specifications - Tech Information
Read More
Helpful HPLC columns you may not know about - White Paper
Read More
High molecular weight compounds that won't retain on Cogent Diamond Hydride column try Cogent Bidentate C8 300 - Tips & Suggestions
Read More
How a pulse from an HPLC pump affect the column and its performance - Tech Information
Read More
How are RSA vials different from all other autosampler vials - FAQ
Read More
How can a finger tight fitting be producing band broadening in HPLC - FAQ
Read More
How can Cogent TYPE-C HPLC columns offer faster results compared to other type of silica based columns - FAQ
Read More
How can I fix split peaks with high back pressure in HPLC analyses - FAQ
Read More
How can I improve accuracy and precision when separating polar compounds by HPLC using Aqueous Normal Phase ANP - FAQ
Read More
How can I make changes to locked cells in the Excel spreadsheet that comes with the HSQ qualification kit - FAQ
Read More
How can I minimize bubble formation in limited volume vials when filling - FAQ
Read More
How can I separate capsaicinoids in hot sauce by HPLC - Tips & Suggestions
Read More
How can sample concentration have an effect on peak shape in HPLC - FAQ
Read More
How do I avoid distorted peak shapes when using a basic mobile phase pH for the analysis of a lipophilic amine - FAQ
Read More
How does ammonium fluoride affect HPLC and LCMS data if using Aqueous Normal Phase ANP methods - FAQ
Read More
How is pressure inside tubing calculated for HPLC - FAQ
Read More
How long will it take for chloroform to degrade the plastic safety coating on the mobile phase bottles if the bottle is broken during a fall - FAQ
Read More
How much pressure can the MicroSolv mobile phase bottles withstand without bursting - FAQ
Read More
How often do I need to clean or wash a Cogent TYPE-C column to keep data precise - FAQ
Read More
How often do I need to do the conditioning procedure for a new Diamond Hydride column - FAQ
Read More
How tight should an autosampler vial cap be to prevent push through of the septa during injection - FAQ
Read More
How to back flush and wash an HPLC column for reuse - Tips & Suggestions
Read More
How to calibrate UV-vis and HPLC detectors with NIST traceable solutions below 230nm - Tips & Suggestions
Read More
How to choose a suitable mobile phase additive for negative ionization mode LCMS - Tips & Suggestions
Read More
How to condition Cogent RP or HPS or Axis HPLC columns for storage - Tips & Suggestions
Read More
How to determine concentration of an impurity in HPLC with the relative response factor RRF - How to
Read More
How to fix a saw tooth pattern in the UV baseline - Tips & Suggestions
Read More
How to get improved retention and peak shape for glutamine glutamic acid and aspartic acid - Tips & Suggestions
Read More
How to improve LOD or detection limits in HPLC - Tips & Suggestions
Read More
How to increase HPLC UV detector response - Tips & Suggestions
Read More
How to keep HPLC columns free of adsorbed contaminants - How To
Read More
How to keep surface treated frits from biofouling - FAQ
Read More
How to minimize HPLC column blockage from most common causes - Tips & Suggestions
Read More
How to separate phospholipids with HPLC - Tips & Suggestions
Read More
How to tighten screw caps properly - Tips & Suggestions
Read More
HPLC Retention time shift troubleshooting - Tips & Suggestions
Read More
HPLC stationary phase can be responsible for a blocked frit- Tips & Suggestions
Read More
I heard that there is not a good alternative to HILIC to achieve sufficient retention for some compounds - FAQ
Read More
I see a strange saw tooth type of pattern in the UV baseline using my Cogent HPLC column what is it and how can I fix it - FAQ
Read More
I see extra peaks in my chromatography when I am not using the same filter - Tips & Suggestions
Read More
If an analyte is only soluble at basic pH can you use a basic mobile phase for my method - FAQ
Read More
If I do not remove gas from my mobile phase solvents what are the consequences - FAQ
Read More
If you are not seeing an expected peak in an HPLC assay - Tips & Suggestions
Read More
Improve or obtain flat baselines in HPLC methods with a gradient - Tips & Suggestions
Read More
Improvement in signal to noise in LCMS with an ANP method - Tips & Suggestions
Read More
Improving peak shapes in an HPLC method in aqueous normal phase ANP - Tips & Suggestions
Read More
Increasing selectivity and resolution for a xylose and ribose method - Tips & Suggestions
Read More
Integrate a peak with a shoulder - How to
Read More
Interpreting mass spectral data - Primer
Read More
Is PEEK tubing or PEEK fittings autoclavable - FAQ
Read More
Is the Cogent Column Filter compatible with a 2.1mm ID column - FAQ
Read More
Is the Excel template included in the Chemical Solutions Qualification kits CFR Part 21.11 compliant - FAQ
Read More
Is the plastic used in the U-2D system autoclavable at 120°C - FAQ
Read More
Is the software for the MicroSolv HPLC PQ Kit supplied on CD or can it be downloaded - FAQ
Read More
Is there a difference in chromatography performance between clear and amber RSA vials - FAQ
Read More
Is there any Bismuth in Soft-Guard™ Septa - FAQ
Read More
Issues with a steep UV trace slope in gradient HPLC methods - Tips & Suggestions
Read More
Know the void volume of an HPLC column - Tips & Suggestions
Read More
Know when to discard an outlier data point in HPLC by using the Q Test - How To
Read More
LFER studies compared to Log D data in describing the Aqueous Normal Phase ANP retention - Tips & Suggestions
Read More
Lower retention is observed when functional group in a compound is ionized - Tips & Suggestions
Read More
Measure signal to noise ratio in an HPLC chromatogram - How to
Read More
Missing peaks using UV detection in HPLC methods - Tech Information
Read More
Mobile Phase recommendation Cogent Diamond Hydride columns for use with serum samples in Aqueous Normal Phase LCMS - Tips & Suggestions
Read More
My LCMS source was getting white film on it and at the same time the background noise was very low so is my Diamond Hydride column bleeding packing material - FAQ
Read More
My retention times are changing after storing my buffer and what could be causing this and tips to help avoid issues - FAQ
Read More
Negative Baselines in HPLC at 214nm - Tips & Suggestions
Read More
No need to use a high pH mobile phases for compounds with a high pKa - Tips & Suggestions
Read More
Obtain a flat baseline in a gradient method without using blank subtraction - How to
Read More
Peak area decreases with increasing flow rate - FAQ
Read More
Percentage of acid needed in Aqueous Normal Phase ANP methods - Tips & Suggestions
Read More
Performance goals or objectives for a routine HPLC method - Tips & Suggestions
Read More
PFAS analysis using glass or plastic vials - Tips and Suggestions
Read More
PFAS and other contaminants leaching into an analysis - Tips & Suggestions
Read More
Polar and non polar peptides analyzed by LCMS with an Aqueous Normal Phase ANP method - Tips & Suggestions
Read More
Poor HPLC peak shape can be due to injection sample mismatch - Tips & Suggestions
Read More
Pre mix your diluent and mobile phase in sample preparation for HPLC - Tips & Suggestions
Read More
Purge metals from HPLC system using EDTA or medronic acid - How To
Read More
Quaternary amines analysis by LCM and finding the right ion - How To
Read More
Random shifting of retention times in HPLC chromatograms - Tips & Suggestions
Read More
Reasons for using direct adaptive Di-Ad HPLC column connectors - Tips & Suggestions
Read More
Reference values for holmium oxide other than 1 nm – Tech Information
Read More
Reliability of wet chemical assays versus HPLC assays - Primer
Read More
Rescaling graphs in the MicroSolv HPLC PQ Kit Excel template - Tips & Suggestions
Read More
Retention and or peak shape for citric acid has changed compared to data from a previous HPLC run - Tips & Suggestions
Read More
Ribose and Xylose analysis without forming Schiff bases - AppNote
Read More
Sample concentration changes can effect retention time in HPLC - Primer
Read More
Sample loop information - FAQ
Read More
Screw and snap cap evaporation studies - Tech Information
Read More
Sensitivity slowly diminishes in HPLC - Tips & Suggestions
Read More
Should I filter my HPLC solvents and buffers before use - FAQ
Read More
Should I use a 1 piece fitting or a 2 piece fitting for HPLC - FAQ
Read More
Should I use methanol as the organic solvent in HPLC when using Aqueous Normal Phase ANP - FAQ
Read More
Since Cogent TYPE-C columns can be used in Reversed Phase or Normal Phase what do you suggest to switch these solvent systems which are not miscible - FAQ
Read More
Since Cogent TYPE-C Silica columns use a transition metal catalyst in production what is the presence of any trace quantity on the surface of the stationary phase- FAQ
Read More
Solving baseline problems in Aqueous Normal Phase ANP methods - Tips & Suggestions
Read More
Spurious peaks from nylon syringe filters with DI water using electrochemical detection can be avoided - Tips & Suggestions
Read More
Store and condition Cogent TYPE-C HPLC columns - How To
Read More
Store and maintain Cogent Diamond Hydride HPLC columns - How To
Read More
System suitability requirements for a USP HPLC method - Tips & Suggestions
Read More
Techniques to prepare a 0.05% solution from a tablet for HPLC injection - How to
Read More
Terminology and criteria for chirality - Primer
Read More
The common names of HPLC column diameters - Primer
Read More
The differences in ion content between clear and amber borosilicate glass vials - Tech Information
Read More
The effect of ionic strength of the mobile phase additive for HPLC columns in Aqueous Normal Phase - Tips & Suggestions
Read More
Theoretical plate estimates indicates column condition - Primer
Read More
Tip for Promoting Analyte Ionization with LCMS – AppNote
Read More
To obtain greater sensitivity than Na adducts for sugars could you add ammonia NH4 instead - FAQ
Read More
Two gradients to use for analysis of hydrophilic and or hydrophobic molecules in the same Aqueous Normal Phase ANP method - Tips & Suggestions
Read More
Type of gradient to use for analysis of hydrophilic and hydrophobic molecules in the same HPLC or LCMS run - Tips & Suggestions
Read More
Types of isomers and suitable HPLC columns for separation - Tips & Suggestions
Read More
Understanding some of the differences between HILIC columns and TYPE-C columns - Tips & Suggestions
Read More
Use a low concentration of salt in your mobile phase to avoid ion suppression and build up on your inlet source - Tips & Suggestions
Read More
Use Teflon bottles for A and B solvents in negative ion mode LCMS - Primer
Read More
Using an Aqueous Normal Phase ANP method will sodium ions interfere with succinate when analyzing sodium succinate - FAQ
Read More
Using Aqueous Normal Phase ANP to your advantage - White Paper
Read More
Using methanol instead of acetonitrile in an HPLC method should be done with caution - Tips & Suggestions
Read More
Using temperature changes for separations of terpenoids with the Cogent Bidentate C18 and UDC-Cholesterol HPLC columns - Tips & Suggestions
Read More
Using triethylamine TEA in Aqueous Normal Phase ANP methods for simple sugars - Tips & Suggestions
Read More
Using two HPLC columns together in a tandem separation for polar and non polar retention - Tips & Suggestions
Read More
UV-vis instrument technology tips shared - Tech Information
Read More
Validation protocol for the PQ kit template - Tips & Suggestions
Read More
What are inosine nucleotides - FAQ
Read More
What are some notable examples of journal articles that feature Aqueous Normal Phase ANP methods in metabolomics studies - FAQ
Read More
What are some of the advantages of using Cogent TYPE-C prep and semi-prep HPLC columns - FAQ
Read More
What are the advantages and disadvantages of acid washing RSA vials - FAQ
Read More
What are the differences between 33 and 51 expansion glass and which should I choose - FAQ
Read More
What are the differences between nylon and PTFE syringe filters for chromatography - FAQ
Read More
What are the pH ranges of common buffers for HPLC - Tips & Suggestions
Read More
What are the temperature and pressure specifications for stainless steel tubing - FAQ
Read More
What are your definitions of normal phase reversed phase and ANP in HPLC - FAQ
Read More
What can cause changing retention times and a peak showing up in my blank with a Silica-C column - FAQ
Read More
What can damage the surface treatment of silanized glass vials - FAQ
Read More
What can I use for a reference solution against Holmium Oxide - FAQ
Read More
What column changes are permitted in USP HPLC methods - FAQ
Read More
What does analytical method validation entail for HPLC and LCMS - Primer
Read More
What does residual volume mean with autosampler vials - FAQ
Read More
What effect does high injection volume have on column performance in Aqueous Normal Phase ANP HPLC- FAQ
Read More
What is a steady state for surfaces like syringe filters - FAQ
Read More
What is a system peak as defined for HPLC - Primer
Read More
What is considered an extractable that comes from syringe filters - FAQ
Read More
What is peak inhibition in LCMS - FAQ
Read More
What is pKa and how is it related to pH in HPLC mobile phases and sample diluents - FAQ
Read More
What is Post Time in an HPLC gradient method - Primer
Read More
What is TFA and when should I use it - Primer
Read More
What is the best way to track samples in U-2D inserts - Tips and Suggestions
Read More
What is the cause of a pressure increase after injections of blanks in HPLC - FAQ
Read More
What is the compatibility of Cogent TYPE-C Silica HPLC columns with UHPLC instruments - FAQ
Read More
What is the difference between a 4um and a 5um particle in a C18 column - FAQ
Read More
What is the difference between AQ brand and low cost syringe filter brands - FAQ
Read More
What is the difference between the terms 45 shore A and 55 shore A in septa - FAQ
Read More
What is the difference between verifications validation and qualification - FAQ
Read More
What is the durability of the SOLVFIL when used with standard mobile phases and buffered mobile phases - FAQ
Read More
What is the effect of extra column volume for different HPLC instruments on the same method - FAQ
Read More
What is the elution order for analytes in the Resolution Test Mixture supplied in the HSQ kit - Tech Information
Read More
What is the largest Internal Diameter for Cogent TYPE-C prep columns - FAQ
Read More
What is the maximum concentration of ammonium fluoride to use in a mobile phase to avoid column damage - Tips & Suggestions
Read More
What is the maximum loading capacity mass injection volume that can be used for a semi prep Cogent TYPE-C HPLC column - FAQ
Read More
What is the maximum pressure the Cogent Column Filters should be used with - FAQ
Read More
What is the maximum salt concentration to use with Cogent TYPE-C HPLC columns with HPLC or LCMS - FAQ
Read More
What is the mobile phase used in the HSQ Kit and how much is used - FAQ
Read More
What is the most effective way to clean HPLC columns after or before use - Tips & Suggestions
Read More
What is the pilot length or dimension X depth for end fittings uses to connect HPLC columns - FAQ
Read More
What is the purpose of a partial slit septa - FAQ
Read More
What is the purpose of a pre slit septa - FAQ
Read More
What is the purpose of the Resolution Test Mixture supplied in your Qualification Kits - FAQ
Read More
What is the purpose of using isopropanol IPA as part of the mobile phase solvent in ANP methods - FAQ
Read More
What is the useable volume in 2mL autosampler vials? - FAQ
Read More
What makes glass borosilicate glass - Tech Information
Read More
What problems can occur when using a dedicated Reversed Phase HPLC instrument for an Aqueous Normal Phase ANP method for the first time - FAQ
Read More
What type of fitting is best to use with the Cogent HPLC and LCMS columns - FAQ
Read More
What type of tubing do I use to connect the guard column holder to analytical columns - FAQ
Read More
What will the pressure be with a mobile phase of 90% methanol and 10% DI water with a 4.6 x 250mm Cogent TYPE-C HPLC column - FAQ
Read More
When and why use Teflon bottles for your mobile phase reservoirs - FAQ
Read More
When I run gradients on my HPLC and switch from one gradient to another my baseline shows as negative and if I auto zero it becomes positive for the remainder of the run but when I start again it is negative - Primer
Read More
When is the acid group of the Cogent UDA HPLC column ionized - Tech Information
Read More
When to use snap caps vs screw caps preventing evaporation - FAQ
Read More
Where a static mixer for HPLC instruments should be placed - Tips & Suggestions
Read More
Which HPLC column do you suggest for analysis of carotene or lycopene - FAQ
Read More
Which HPLC column internal diameter should I use for LCMS - FAQ
Read More
Which membrane filter disc is best to use with aqueous buffers - FAQ
Read More
Which parameters can be determined with the supplied solutions in the MicroSolv PQ Excel template - FAQ
Read More
Which size guard column should I use with my 1mm Cogent 2.o column - FAQ
Read More
Which vial type should I use for a low volume sample study of proteins - FAQ
Read More
Why am I observing broad split peaks in Aqueous Normal Phase ANP when using acetonitrile and methanol diluents - FAQ
Read More
Why am I seeing multiple peaks in HPLC runs of fructose - Tips & Suggestions
Read More
Why am I seeing two peaks for quaternium15 Dowicil-75 in LCMS - FAQ
Read More
Why are pipettors not recommended for dispensing non aqueous liquids accurately and precisely - FAQ
Read More
Why are the Cogent Silica-C columns more stable than other silica columns - FAQ
Read More
Why are the same size autosampler vials listed as 2mL 1.8mL or 1.5mL by different suppliers - FAQ
Read More
Why do I have higher pressure at a lower flow rate in my HPLC runs - FAQ
Read More
Why do I see large intermittent pressure spikes in HPLC runs and can it be a defective column - FAQ
Read More
Why does MicroSolv have 5 tiers or brands of autosampler vials - FAQ
Read More
Why is isopropanol rarely used as a solvent in HPLC or LCMS methods - FAQ
Read More
Why would I want to use an HPLC column that is not end capped - FAQ
Read More
Wikipedia reference for use of pipets with organic solvents - Primer
Read More
Will a different guard column hardware system different from the Cogent system affect my results when using a Cogent column - FAQ
Read More
Will acid washing autosampler vials have consequences or affect my chromatography - FAQ
Read More
Will different guard columns packed by different column packers be equivalent - INTERNAL ONLY
Read More
Will I protect HPLC columns from samples that get permanently adsorbed to the column by using a syringe filter - FAQ
Read More
Will phosphates precipitate in an HPLC column - FAQ
Read More
Will TFA permanently alter retention / selectivity of the Cogent TYPE-C silica columns - FAQ
Read More
Will using the Cogent Column Filters change my current HPLC results - FAQ
Read More
Will your qualification kits for UV-vis be appropriate for my spectrophotometer - FAQ
Read More