Category: Troubleshooting Baseline and Peak Issues
/
/
/

  • Browse troubleshooting tips for resolving HPLC issues, including retention changes, peak‑shape problems, baseline noise, vial interferences, mobile‑phase concerns, and column behavior.


Add 10 micro molar EDTA to Mobile Phase for Better Peak Shapes - Tips & Suggestions
Read More
Adjusted retention time hold up time - Primer
Read More
Adsorption of Analytes Occurs Rapidly in Autosampler Vials – AppNote
Read More
Ammonium Acetate in LCMS Requires Attention to Cleaning - Tips & Suggestions
Read More
Ammonium Acetate or Triethylamine TEA Use with Cogent HPLC Columns - Tips and Suggestions
Read More
Analyte Recovery Changes Between Days - Case Study - Troubleshooting
Read More
Analyzing metformin in plasma samples how do I obtain reproducible results and peak shapes - FAQ
Read More
Autosampler Vials - Engineered for Reliable Compatibility - Tech Information
Read More
Back Flush and Wash an HPLC Column for Reuse - Tips and Suggestions
Read More
Back Flushing an HPLC Column Risks and Benefits - Tech Information
Read More
Back Pressure That is Lower than Normal Using a Cogent Diamond Hydride HPLC Column - Tech Information
Read More
Baseline Noise with Cogent Diamond Hydride HPLC column - Tips and Suggestions
Read More
Biological Extracts - Troubleshooting for Diminished Peak Height Using Cogent Diamond Hydride™ Columns - Tech Information
Read More
Broad or Split Peaks in ANP When Using Methanol ‑ Rich Diluents - Tips and Suggestions
Read More
Broad Peaks That are Non Symmetrical in LCMS in Reversed Phase Solutions - Troubleshooting
Read More
Bubbles Forming When Using Inlet Filters for HPLC Mobile Phases - Tips & Suggestions
Read More
Bubbling or Fizzing Coming from a New Cogent TYPE-C Column - Tech Information
Read More
Calculate assay of lisinopril dihydrate based on the anhydrous form - How to
Read More
Can Low Quantitative Results in HPLC be Due to Autosampler Vials or Caps - HPLC Primer
Read More
Can rapid changes in column back pressure damage an HPLC column - FAQ
Read More
Causes of an HPLC column appearing to lack sensitivity in LCMS - Tips & Suggestions
Read More
Changing Column ID Means You Must Change your Gradient - Tips & Suggestions
Read More
Changing in the Mobile Phase with Acids to One with Ammonium Salts. Tips & Suggestions
Read More
Check for High Pressure Traced to the HPLC Pump Module - Tips & Suggestions
Read More
Choose an Appropriate Re-Equilibration or Post Time for Gradient HPLC - Tech Information
Read More
Citric acid retention and peak shape has changed compared to data from a previous run what happened - FAQ
Read More
Cleaning Cogent TYPE-C Silica Based HPLC Columns - Tips and Suggestions
Read More
Cleaning SOP for Cogent Diamond Hydride When Using Blood Samples - Tips and Suggestions
Read More
Column Cleaning and Care in UHPLC Columns - Tips & Suggestions
Read More
Column Filters vs Guard Columns Protecting HPLC Columns - HPLC Primer
Read More
Common cause of excessive back pressure in HPLC columns - FAQ
Read More
Constant Pressure Method on two Instruments Producing Different Flow Rates- Troubleshooting
Read More
Contaminants including PFAS leaching into an analysis - Tips & Suggestions
Read More
Cysteine analysis tips for LCMS - Tips & Suggestions
Read More
Difficulties with wavelength accuracy readings while performing a PQ of an HPLC - Tips & Suggestions
Read More
Do You Really Need High pH for Retention in HPLC - Tips and Suggestions
Read More
Dwell volume effect on HPLC analyte retention in gradient methods - Primer
Read More
Effects of Washing and Re-using Autosampler Vials on Sample Loss and Contamination - Tech Information
Read More
Eliminate Retention Time Drift in LCMS With Aqueous Normal Phase ANP Methods - Tips & Suggestions
Read More
Eliminating High Background Noise in New Cogent HPLC Columns - Tips and Suggestions
Read More
Eliminating Shoulder Peaks in HPLC Using C18 Columns - Tips and Suggestions
Read More
Extra Peaks When Not Using the Same Syringe Filter - Troubleshooting
Read More
Factors that affect sensitivity in HPLC - Tech Information
Read More
Ferrule Selection Guidance - HPLC Primer
Read More
Finger Tightened Fittings Can Produce Band Broadening in HPLC - HPLC Primer
Read More
Flat Baselines in Gradient HPLC Without Blank Subtraction - Tech Information
Read More
Fluctuations in readings when using the UV-Vis Calibration Kit - Tech Information
Read More
For Sugars Analyzed by LCMS Sodium Acetate is recommended for Sensitivity of Na Adducts - Tips & Suggestions
Read More
Formic Acid Improves Peak Shapes Retention and Carryover for Polar Compounds with the Cogent Diamond Hydride HPLC Column - Tips & Suggestions
Read More
Ghost peaks appearing in results using a gradient with TFA which can degrade with time - Tips & Suggestions
Read More
High Injection Volume Effect on Column Performance in Aqueous Normal Phase Methods - Tech Information
Read More
High Pressure Develops after Flushing a Cogent Diamond Hydride HPLC Column with Acetonitrile Cause and Solution - FAQ
Read More
High‑Molecular‑Weight Compounds Fail to Retain on the Cogent Diamond Hydride Column — and the Correct Column to Use - Tips and Suggestions
Read More
Holmium Oxide for HPLC UV Detector Performance Qualification - Tips and Suggestions
Read More
How Can Autosampler Vials Cause Missed Injections in HPLC - HPLC PRIMER
Read More
How Can I Minimize Bubble Formation in Limited Volume Vials When Filling - HPLC Primer
Read More
How can sample concentration have an effect on peak shape in HPLC - FAQ
Read More
How do I Avoid Distorted Peak Shapes When Using a Basic Mobile Phase pH for the Analysis of a Lipophilic Amine - Tips & Suggestions
Read More
How do I know if a crimped cap on a vial has a proper seal - HPLC Primer
Read More
How Pulsations from an HPLC Pump Can Impact Column Performance - Tech Information
Read More
How Tight Should an Autosampler Vial Cap be to Prevent Push Through of the Septa During Injection - HPLC Primer
Read More
How to improve LOD or detection limits in HPLC - Tips & Suggestions
Read More
HPLC Retention Time Shift Troubleshooting - Tips and Suggestions
Read More
HPLC stationary phase can be responsible for a blocked frit- Tips & Suggestions
Read More
I see a strange saw tooth type of pattern in the UV baseline using my Cogent HPLC column what is it and how can I fix it - FAQ
Read More
Importance of Fresh Cutting Edges in Tubing– Tech Information
Read More
Improve or Obtain Flat Baselines in HPLC Methods with a Gradient - Tips and Suggestions
Read More
Improving peak shapes in an HPLC method in Aqueous Normal Phase ANP - Tips & Suggestions
Read More
Improving Separation of Two Peaks in Reversed Phase HPLC - Tips and Suggestions
Read More
Inconsistent peak heights obtained for glucosamine in HPLC - Tips & Suggetions
Read More
Injection Guidance for Cogent TYPE-C HPLC Columns - Tips and Suggestions
Read More
Inorganic Buffers Use for HPLC UV Analysis of Citric Acid - Tips & Suggestions
Read More
Integrate a peak with a shoulder - How to
Read More
Is Higher Pressure Generated on The Cogent 2.o HPLC columns Than 4um Phases - FAQ
Read More
Is TFA or formic acid better as an acidic mobile phase additive for Cogent TYPE-C columns - FAQ
Read More
Isopropanol Rarely Used as a Solvent in HPLC or LCMS Methods - HPLC Primer
Read More
Issues with a steep UV trace slope in gradient HPLC methods - Tips & Suggestions
Read More
Know when to discard an outlier data point in HPLC by using the Q Test - How To
Read More
Lower Retention When Functional Group in a Compound Should be Ionized - Troubleshooting Tips
Read More
Maximum Concentration of Ammonium Fluoride in a Mobile Phase - Tips and Suggestions
Read More
Maximum recommended flow rates for the different filter pore sizes. – Tech Information
Read More
Measure signal to noise ratio in an HPLC chromatogram - How to
Read More
Missing Peaks Using UV Detection in HPLC methods - Tech Information
Read More
Multiple peaks in HPLC runs of fructose - Tips and Suggestions
Read More
Negative Baselines Observed in HPLC Runs at 214 nm - Tips & Suggestions
Read More
No Buffer Migration Does Not Mean the Zero‑Flow Capillary is Defective - Troubleshooting
Read More
No Peaks for Succinic Acid or Alpha-Ktoglutarate With the Cogent Diamond Hydride LC-MS Column - Tips & Suggestions
Read More
Not Seeing an Expected Peak in an HPLC Assay - Tips and Suggestions
Read More
Peak area decreases with increasing flow rate - FAQ
Read More
pH Tanges of Common Buffers Used in HPLC - HPLC Primer
Read More
Phosphate Precipitation Risks in HPLC Columns - HPLC Primer
Read More
Phosphorylated Compounds Analyzed with Cogent Diamond Hydride Columns - Tips and Suggestions
Read More
Polar and Mixed‑Polarity Metabolites Strategy Using Panel Method Cogent Diamond Hydride - Tips and Suggestions
Read More
Poor HPLC peak shape can be due to injection sample mismatch - Tips & Suggestions
Read More
Poor peak shape for ethylenediamine in LCMS analyses - Tech Information
Read More
Positive Ion Mode LCMS Retention of Polar Compounds - Tips and Suggestions
Read More
Pressure Increase at a Lower Flow Rate - HPLC Primer
Read More
PTFE that is Skived vs Cast in Headspace Septa Affecting Quantitation - Tech Information
Read More
Quaternary Amines Analysis by LCMS Finding the Right Ion - Tech Information
Read More
Remove a Ferrule That is Stuck in an HPLC System or Column - Tips & Suggestions
Read More
Remove Gas from Mobile Phase Solvents - Tips and Suggestions
Read More
Repair a Blocked Frit in an HPLC column - Tips and Suggestions
Read More
Restoring a Cogent Diamond Hydride Column After Air Exposure - Ran Out of Mobile Phase - Troubleshooting
Read More
Restoring the Initial Method Results Analyzing AMP ADP ATP UDP and GPT in Biological Extracts - Troubleshooting
Read More
Retention And or Peak Shape for Citric Acid has Changed Compared to Data from a Previous HPLC Run - Tips & Suggestions
Read More
Retention Decrease as Mobile Phase Water Content Increases on a Cogent Bidentate C18 Column - Troubleshooting
Read More
Retention Time Changes in Biological Extracts Using Ammonium Acetate - Troubleshooting.
Read More
Retention Time Difference in the Resolution Test Mixture on Different Systems Does Not Impact the Integrity of Data - Tech Informaton
Read More
Retention Times Vary from Instrument to Instrument - Tech Information
Read More
Sample Diluents Should Match Your Starting Mobile Phase - Tips & Suggestions
Read More
Saw Tooth Pattern in the UV Baseline - Troubleshooting
Read More
Selectivity Modification in an ANP Method Using Different Mobile Phase pH - Tips & Suggestions
Read More
Separation of Phenylephrine HCl Acetaminophen and Dextromethorphan - Tips and Suggestions
Read More
Since Cogent TYPE-C Silica columns use a transition metal catalyst in production what is the presence of any trace quantity on the surface of the stationary phase- FAQ
Read More
Sodium Ion Interference in ANP Methods: Challenges in Analyzing Sodium Succinate - Tips & Suggestions
Read More
Split Peaks and High Back Pressure in HPLC Analyses - Troubleshooting
Read More
Storing Cogent Diamond Hydride HPLC Columns - Tech Information
Read More
Techniques to prepare a 0.05% solution from a tablet for HPLC injection - HPLC Primer
Read More
TFA Compatibility with Delrin Type Fittings in HPLC - Tech Information
Read More
The effect of ionic strength of the mobile phase additive for HPLC columns in Aqueous Normal Phase - Tips & Suggestions
Read More
Troubleshooting Problems With Poor HPLC Results Before Examining the Column - Tips & Suggestions
Read More
Two Peaks for Quaternium-15 or Dowicil-75 in LCMS Data - Tech Information
Read More
Using Non‑Cogent Guard Column Hardware With Cogent HPLC Columns - Tech Information
Read More
Verifying New Cogent HPLC Column Performance - Tech Information
Read More
What are some common sources of variance during sample preparation in an analytical application - FAQ
Read More
What is pKa and how is it related to pH in HPLC mobile phases and sample diluents - FAQ
Read More
What is the cause of a pressure increase after injections of blanks in HPLC - FAQ
Read More
What is the effect of extra column volume for different HPLC instruments on the same method - FAQ
Read More
What problems can occur when using a dedicated Reversed Phase HPLC instrument for an Aqueous Normal Phase ANP method for the first time - FAQ
Read More
What will the pressure be with a mobile phase of 90% methanol and 10% DI water with a 4.6 x 250mm Cogent TYPE-C HPLC column - FAQ
Read More
When and why use Teflon bottles for your mobile phase reservoirs - FAQ
Read More
When I run gradients on my HPLC and switch from one gradient to another my baseline shows as negative and if I auto zero it becomes positive for the remainder of the run but when I start again it is negative - Primer
Read More
White Film on an LC-MS Source with Background Noise was Very Low - Tech Information
Read More
Why am I observing broad split peaks in Aqueous Normal Phase ANP when using acetonitrile and methanol diluents - FAQ
Read More
Why am I seeing two peaks for quaternium15 Dowicil-75 in LCMS - FAQ
Read More
Why are Pipettors not Recommended for Dispensing Non Aqueous Liquids Accurately and Precisely - FAQ
Read More
Why do I see large intermittent pressure spikes in HPLC runs and can it be a defective column - FAQ
Read More
Why doesn't triphenylamine a tertiary amine retain in Aqueous Normal Phase ANP - FAQ
Read More