Column Filters, for HPLC, 0.5 um Stainless Steel filter element and All-PEEK body. Disposable, with end plugs. Black. Cogent Brand. 10/PK.

Additional Info:

The Cogent In‑Line Column Filter (0.5 µm) in the 10‑pack configuration is the most popular column‑protection solution for laboratories running routine analytical HPLC workflows at scale. This disposable pre‑column filter protects analytical columns from undissolved particulates, sample debris, and pump‑seal shedding, all of which can shorten column life and compromise performance.

Each unit contains a 0.5 µm stainless steel filter element housed in an all‑PEEK body, providing excellent chemical compatibility while maintaining a metal‑free flow path outside the filter element. The larger pack size is ideal for high‑throughput environments, reducing per‑unit cost and minimizing downtime associated with reordering.

A universal column connection fits all standard analytical HPLC column threads and pilot lengths. Installation is quick and repeatable using hand tightening followed by a quarter‑turn wrench, making replacement straightforward during routine maintenance.

Key Features

Effective Column Protection

  • Prevents particulates from entering the analytical column

  • Extends column lifetime and maintains resolution

  • Protects against common pump‑seal debris

0.5 µm Stainless Steel Filter Element

  • Fine particulate retention for analytical HPLC

  • Balanced protection with minimal pressure impact

  • Consistent, reproducible performance

All‑PEEK Disposable Housing

  • Broad chemical compatibility

  • Lightweight, corrosion‑resistant construction

  • Disposable design eliminates cleaning or regeneration

Universal HPLC Connection

  • Fits all analytical HPLC column threads and pilot lengths

  • Simple hand‑tight + quarter‑turn wrench installation

  • Easily integrated into existing systems

High‑Value Pack Size

  • 10 filters per package

  • Lower cost per filter compared to smaller pack sizes

  • Ideal for high‑volume and production laboratories

Usage & Replacement Guidance

When in‑line column filters are installed, system backpressure should be monitored. A gradual increase in pressure typically indicates filter loading.

To replace:

  1. Reduce system pressure to atmospheric

  2. Disconnect the in‑line filter

  3. Dispose of the used filter

  4. Install a new unit and resume operation

These devices are also commonly referred to as pre‑column filters due to their installation position upstream of the analytical column.

Pressure Rating & Compatibility

  • Maximum pressure: 4,500 psi

  • Compatible with: Analytical HPLC systems

  • Not recommended for: UHPLC pressure ranges

A 2.0 µm version is available for applications requiring lower restriction.

Typical Applications

  • Routine analytical HPLC

  • Column life‑extension programs

  • Method development and validation

  • Sample matrices with particulate risk

  • High‑throughput laboratory operations

 

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media