CUSTOM ITEM: HPLC Column, RP C18, 5um, 4.0mm ID x 250mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68518‑25P‑4 Cogent RP C18 HPLC Column is designed for maximum separation performance, utilizing 5 µm particles and fully double end‑capped C18 bonding to deliver reliable retention, improved peak symmetry, and consistent analytical results.

Manufactured using high‑purity silica with traditional octadecylsilane (C18) chemistry, this stationary phase provides:

  • Complete end‑capping to minimize silanol interactions

  • Improved performance for polar and basic analytes

  • Consistent and reproducible chromatography across methods

This column is widely used as a starting point for new methods and as a USP L1 alternate for 5 µm analytical applications.

250 mm Length – Maximum Separation & Peak Capacity

  • Highest resolving power in the 4.0 mm RP C18 range

  • Maximizes peak capacity for highly complex mixtures

  • Ideal for closely related analytes and difficult separations

  • Provides longer retention for hydrophobic compounds

  • Best suited for final method optimization and highest purity separations

This format is selected when shorter columns do not provide sufficient resolution or retention.

4.0 mm ID – Solvent‑Saving Analytical Performance

  • Comparable chromatographic behavior to 4.6 mm ID columns

  • Reduces mobile phase consumption and waste

  • Typical flow rate range: ~0.8–1.2 mL/min

  • Optimal starting range: ~0.85–1.10 mL/min

Benefits:

  • Lower solvent usage

  • Reduced operating cost

  • Compatible with standard HPLC systems

Flow Rate & System Considerations (4.0 mm ID, 5 µm)

  • Suitable for conventional HPLC systems

  • Supports a wide range of flow conditions

  • Well suited for:

    • Viscous mobile phases

    • Long gradients

    • Extended analytical runs

Why Choose RP C18 (5 µm)

Robust & Reliable Operation

  • Ideal for routine analytical workflows and method development

  • Lower backpressure relative to smaller particle sizes

  • Suitable for long method lifetimes and consistent performance

Reliable Hydrophobic Retention

  • Strong reversed‑phase retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids

  • Provides greater retention than C8 phases

Method Development & USP Compatibility

  • Ideal for new method development and optimization

  • Suitable for USP L1 methods using 5 µm particles

  • Reliable alternate or replacement column

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Better performance for basic analytes

High Purity Silica

  • Consistent chromatographic performance

  • Reduced variability across runs

Durable & Cost‑Efficient

  • Long column lifetime

  • Reduced system wear

  • Lower maintenance frequency

Typical Applications

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Complex multi‑component mixtures

  • Method development and validation

  • USP L1 reversed‑phase workflows

Important Usage Notes

  • Compatible with standard HPLC systems

  • Ideal for maximum‑resolution analytical workflows

  • Best suited when separation performance and peak capacity are critical

  • Optimize method conditions to balance resolution and run time

Made‑to‑Order & Pricing Information

This is a custom, made‑to‑order item.

  • Orders cannot be canceled once placed

  • Custom items are non‑returnable