HPLC Column, RP C18, 5um, 2.1mm ID x 250mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68518‑25P‑2 Cogent RP C18 HPLC Column is engineered for maximum separation performance in LC‑MS and analytical workflows, utilizing 5 µm particles and fully double end‑capped C18 bonding to deliver reliable retention, excellent peak shape, and consistent results.

Manufactured using high‑purity silica with traditional octadecylsilane (C18) bonding, this stationary phase provides:

  • Complete end‑capping to minimize silanol interactions

  • Improved peak symmetry for polar and basic analytes

  • Consistent, reproducible chromatography across demanding methods

This column is a trusted choice for USP L1 method substitution, method development, and high‑resolution LC‑MS workflows.

250 mm Length – Maximum Resolution & Peak Capacity

  • Highest resolving power in the 2.1 mm RP C18 range

  • Maximizes peak capacity for complex mixtures

  • Ideal for closely related compounds and trace-level separations

  • Provides extended retention for hydrophobic analytes

  • Best suited for final method optimization and high‑purity analysis

This configuration is selected when shorter columns cannot provide sufficient resolution or separation.

Flow Rate & System Considerations (2.1 mm ID, 5 µm)

  • Typical flow rate range: ~0.2–0.4 mL/min

  • Optimal starting range: ~0.20–0.30 mL/min

Requires:

  • HPLC or LC‑MS system capable of stable low‑flow delivery

  • Low‑volume detector flow cell for optimal sensitivity

  • Precision injection system

⚠️ Systems must maintain accurate and consistent low‑flow performance for best results

Why Choose RP C18 (5 µm

Robust & Reliable Operation

  • Ideal for routine analytical workflows and method development

  • Lower backpressure relative to smaller particle sizes

  • Suitable for long, reproducible analytical methods

Reliable Hydrophobic Retention

  • Strong reversed‑phase retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids

  • Provides greater retention than C8 phases

Method Development & USP Compatibility

  • Ideal for new method development and optimization

  • Suitable for USP L1 methods using 5 µm particles

  • Reliable alternate or replacement column

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Enhances performance for polar and basic analytes

High Carbon Load

  • Increased retention and loading capacity

  • Greater flexibility across a wide range of analytes

Low Column Bleed

  • Suitable for sensitive detection methods (LC‑MS and UV)

  • Cleaner baselines and improved data quality

High Purity Silica

  • Consistent chromatographic performance

  • Reduced variability between runs and batches

Typical Applications

  • LC‑MS analytical workflows

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Complex multi‑component mixtures

  • Method development and validation

  • USP L1 reversed‑phase methods

Important Usage Notes

  • Designed for low‑flow analytical workflows (2.1 mm ID)

  • Requires stable low‑flow system capability

  • Ideal for maximum‑resolution separations and complex mixtures

  • Optimize flow rate and gradient conditions for best performance

 