HPLC Column, RP C18, 5um, 4.6mm ID x 250mm Length, 100A. Cogent Brand. 1 EA.
Additional Info:
The 68518‑25P Cogent RP C18 HPLC Column is engineered for maximum separation performance, featuring 5 µm particles and fully double end‑capped C18 bonding to deliver excellent peak shape, reliable retention, and reproducible results.
Manufactured using high‑purity silica with traditional octadecylsilane (C18) bonding, this stationary phase provides:
Complete end‑capping to minimize silanol interactions
Improved peak symmetry for polar and basic analytes
Consistent and robust chromatographic performance
This column is a trusted choice as a primary analytical column, a starting platform for new method development, and a reliable alternate for USP L1 methods using 5 µm phases.
250 mm Length – Maximum Separation & Peak Capacity
Highest resolving power in the 4.6 mm RP C18 range
Maximizes peak capacity for highly complex mixtures
Ideal for closely related analytes and challenging separations
Provides extended retention for hydrophobic compounds
Best suited for final method optimization and highest purity separations
This format is selected when shorter columns (50 mm or 100 mm) do not provide adequate resolution or separation.
4.6 mm ID – Standard Analytical Performance
Industry‑standard HPLC column dimension
Compatible with all conventional HPLC systems
Typical flow rate range: ~0.8–1.5 mL/min
Optimal starting range: ~1.0–1.2 mL/min
Provides:
Strong detector response
High reproducibility
Easy method transfer across laboratories
Flow Rate & System Considerations (4.6 mm ID, 5 µm)
Suitable for conventional HPLC systems
Supports a wide range of flow conditions
Well suited for:
Viscous mobile phases
Extended gradients
Long, high‑resolution analytical runs
Why Choose RP C18 (5 µm)
Robust & Reliable Operation
Ideal for routine analytical workflows and method development
Lower backpressure relative to smaller particle sizes
Suitable for long method lifetimes and consistent results
Reliable Hydrophobic Retention
Strong reversed‑phase retention for hydrophobic and neutral compounds
Excellent for long‑chain fatty acids
Provides greater retention than C8 phases
Method Development & USP Compatibility
Ideal for new method development and optimization
Suitable for USP L1 methods using 5 µm particles
Reliable alternate or replacement column
Cogent RP C18™ Advantages
Fully End‑Capped Surface
Minimizes secondary interactions
Improves peak symmetry
Better performance for basic analytes
High Carbon Load
Enhanced retention and loading capacity
Increased method flexibility
Low Column Bleed
Suitable for sensitive detection methods (UV and LC‑MS)
Cleaner baselines and improved data quality
High Purity Silica
Consistent chromatographic performance
Reduced variability between runs and columns
Typical Applications
Pharmaceutical and QC analysis
Hydrophobic and neutral compound separations
Long‑chain fatty acids
Complex multi‑component mixtures
Method development and validation
USP L1 reversed‑phase workflows
Important Usage Notes
Compatible with standard HPLC systems
Ideal for maximum‑resolution analytical workflows
Best suited when complex separations require high peak capacity
Optimize method conditions to balance resolution and run time