This items is made to order and is not returnable and order cannot be canceled.

CUSTOM ITEM: HPLC Column, RP C18, Wide Pore, 5um, 4.0mm ID x 150mm Length, 300A. Cogent Brand. 1 EA.

Additional Info:

The 68518‑15P‑4‑3M Cogent RP C18 Wide Pore HPLC Column is engineered for maximum‑resolution separations of large molecular weight analytes, combining 5 µm particles with a 300 Å wide‑pore structure to deliver enhanced analyte access, improved recovery, and consistent chromatographic performance.

Manufactured using high‑purity silica with traditional octadecylsilane (C18) bonding and fully double end‑capped, this stationary phase provides:

  • Reduced silanol interactions

  • Improved peak shape for proteins, peptides, and large polar analytes

  • Excellent reproducibility and durability

The 300 Å pore size enables large molecules to fully interact with the stationary phase, eliminating restricted diffusion and reduced recovery seen with standard 100 Å columns.

150 mm Length – Maximum Resolution & Peak Capacity

  • Highest resolving power in the 4.0 mm wide‑pore C18 range

  • Maximizes peak capacity for complex biomolecule mixtures

  • Ideal for closely related proteins, peptides, and macromolecules

  • Preferred for final method optimization and high‑purity separations

  • Longer run times compared to 50 mm and 100 mm formats

This configuration is best suited when maximum separation performance is required over speed.

4.0 mm ID – Solvent‑Saving Analytical Performance

  • Comparable chromatographic behavior to 4.6 mm ID columns

  • Reduces mobile phase consumption and waste

  • Typical flow rate range: ~0.8–1.2 mL/min

  • Optimal starting range: ~0.85–1.10 mL/min

Benefits:

  • Lower solvent usage

  • Reduced operating cost

  • Compatible with standard HPLC systems

Flow Rate & System Considerations (4.0 mm ID, 5 µm, 300 Å)

  • Suitable for conventional HPLC systems

  • Supports higher flow rates compared to smaller particle sizes

  • Appropriate for:

    • Viscous mobile phases

    • Extended gradients

    • Routine and demanding analytical workflows

Why Choose Wide Pore (300 Å) C18

Designed for Large Molecules

  • Enables efficient separation of:

    • Proteins

    • Peptides

    • Oligonucleotides

  • Eliminates mass transfer limitations of 100 Å stationary phases

Improved Recovery & Peak Shape

  • Greater analyte penetration into stationary phase

  • Improved peak symmetry and reproducibility

Maintains Reversed‑Phase Selectivity

  • Retains classic C18 hydrophobic interaction behavior

  • Suitable for lipids and long‑chain fatty acids

RP C18 (5 µm) Performance Advantages

Robust & Reliable Operation

  • Ideal for routine analytical workflows and method development

  • Lower backpressure relative to smaller particle sizes

  • Well suited for long method lifetimes and consistent performance

Reliable Hydrophobic Retention

  • Strong retention for hydrophobic and neutral compounds

  • Effective for lipids, fatty acids, proteins, and peptides

  • Provides greater retention than C8 phases

Method Development Versatility

  • Ideal for new method development and optimization

  • Suitable for USP L1 wide‑pore applications

  • Flexible across a wide range of analytes

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Better performance for polar and basic analytes

High Purity Silica

  • Consistent chromatographic results

  • Reduced variability between runs

Durable & Cost‑Efficient

  • Long column lifetime

  • Reduced system strain

  • Lower maintenance frequency

Typical Applications

  • Protein and peptide separations

  • Oligonucleotide analysis

  • Biomolecule HPLC and LC‑MS workflows

  • Lipids and hydrophobic compounds

  • Long‑chain fatty acids

  • Complex biomolecule mixtures requiring maximum resolution

Important Usage Notes

  • Designed for large molecule separations using 300 Å pore media

  • Compatible with standard HPLC systems

  • Ideal for applications requiring maximum resolution and recovery

  • Optimize flow rate and mobile phase to balance resolution and run time

Custom Order Information

This product is a made‑to‑order item.

  • Orders cannot be canceled once placed

  • Custom items are non‑returnable

Please contact Customer Service for lead time and ordering assistance.

Custom Order Item. Inquire for more information.

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media