CUSTOM ITEM: HPLC Column, RP C18, 5um, 4.0mm ID x 150mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68518‑15P‑4 Cogent RP C18 HPLC Column is designed for maximum‑resolution analytical separations, featuring 5 µm particles and fully double end‑capped C18 bonding to deliver reliable retention, excellent peak shape, and consistent performance.

Manufactured using high‑purity silica with traditional octadecylsilane (C18) bonding, this stationary phase provides:

  • Complete end‑capping to minimize silanol interactions

  • Improved peak symmetry for polar and basic analytes

  • Consistent and reproducible chromatography

This column is widely used as a primary analytical column, a starting point for new methods, and as an alternate for USP L1 methods using 5 µm particle phases.

150 mm Length – Maximum Resolution

  • Highest resolving power in the 4.0 mm RP C18 range

  • Maximizes peak capacity for complex mixtures

  • Ideal for closely related compounds and difficult separations

  • Preferred for final method optimization and high‑purity analysis

  • Longer run times compared to 50 mm and 100 mm formats

This column is selected when maximum separation performance is required over speed.

4.0 mm ID – Solvent‑Saving Analytical Performance

  • Comparable chromatographic behavior to 4.6 mm ID columns

  • Reduces mobile phase consumption and waste

  • Typical flow rate range: ~0.8–1.2 mL/min

  • Optimal starting range: ~0.85–1.10 mL/min

Benefits:

  • Lower solvent usage

  • Reduced operating cost

  • Compatible with standard HPLC systems

Flow Rate & System Considerations (4.0 mm ID, 5 µm)

  • Suitable for conventional HPLC systems

  • Supports higher flow rates compared to smaller particle sizes

  • Well suited for:

    • Viscous mobile phases

    • Longer gradients

    • Routine and extended analytical runs

Why Choose RP C18 (5 µm)

Robust & Reliable Operation

  • Ideal for routine analytical workflows

  • Lower backpressure relative to smaller particle sizes

  • Suitable for long method lifetimes and consistent results

Reliable Hydrophobic Retention

  • Strong reversed‑phase retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids

  • Provides greater retention than C8 phases

Method Development & USP Compatibility

  • Ideal for new method development and optimization

  • Suitable for USP L1 methods using 5 µm particles

  • Reliable alternate or replacement column

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Better performance for basic analytes

High Purity Silica

  • Consistent chromatographic performance

  • Reduced variability across runs

Durable & Cost‑Efficient

  • Long column lifetime

  • Reduced system strain

  • Lower maintenance frequency

Typical Applications

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Complex analytical methods

  • Method development and validation

  • USP L1 reversed‑phase workflows

Important Usage Notes

  • Compatible with standard HPLC systems

  • Ideal for maximum‑resolution analytical methods

  • Best suited when complex separations require high peak capacity

  • Optimize flow rate and mobile phase for desired resolution vs run time balance

Made‑to‑Order & Pricing Information

This is a custom, made‑to‑order item.

  • Orders cannot be canceled once placed

  • Custom items are non‑returnable

Custom Order Item. Inquire for more information.