HPLC Column, RP C18, 5um, 2.1mm ID x 150mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68518‑15P‑2 Cogent RP C18 HPLC Column is a durable, reversed‑phase column designed for maximum‑resolution analytical separations, featuring 5 µm particles and fully double end‑capped C18 bonding for consistent retention and reliable performance.

Manufactured using high‑purity silica with traditional octadecylsilane (C18) chemistry, this stationary phase:

  • Uses complete end‑capping to minimize silanol interactions

  • Improves peak shape for polar and basic analytes

  • Provides robust and reproducible chromatography

This column is ideal as a USP L1 alternate column and a dependable solution for routine analysis and high‑resolution LC‑MS workflows.

150 mm Length – Maximum Resolution for LC‑MS

  • Highest resolving power in the 2.1 mm RP C18 (5 µm) range

  • Maximizes peak capacity for complex mixtures

  • Ideal for closely related analytes and difficult separations

  • Preferred for LC‑MS workflows requiring detailed resolution

  • Longer run times compared to 50 mm and 100 mm formats

This format is best suited when maximum separation and purity are prioritized over speed.

Flow Rate & System Requirements (2.1 mm ID, 5 µm)

  • Typical flow rate range: ~0.2–0.4 mL/min

  • Optimal starting range: ~0.20–0.30 mL/min for maximum resolution

Requires:

  • HPLC or LC‑MS system capable of stable low‑flow delivery

  • Low‑volume detector flow cell

  • Precision injection system

✅ Operates under standard high‑pressure HPLC conditions ✅ Produces lower backpressure than 3 µm and 1.8 µm columns, while remaining a high‑pressure analytical column

Why Choose RP C18 (5 µm)

High‑Pressure Robustness & Stability

  • Designed for standard HPLC high‑pressure operation

  • Lower backpressure relative to smaller particle sizes

  • Ideal for rugged, long‑term analytical methods

Reliable Hydrophobic Retention

  • Strong reversed‑phase retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids

  • Provides longer retention than C8 phases

Method Development & USP Compatibility

  • Ideal for method development and optimization

  • Suitable for USP L1 methods using 5 µm particle columns

  • Reliable alternate or replacement column

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Enhances performance for basic analytes

High Purity Silica

  • Consistent chromatographic results

  • Reduced variability across runs and columns

Durable & Cost‑Efficient

  • Longer column lifetime vs smaller particle sizes

  • Reduced system strain

  • Lower maintenance and replacement costs

Typical Applications

  • LC‑MS analytical workflows

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Complex mixture separations

  • USP L1 reversed‑phase methods

Important Usage Notes

  • Operates under standard high‑pressure HPLC conditions

  • Requires stable low‑flow capability for 2.1 mm ID columns

  • Ideal for maximum‑resolution analytical workflows

  • Best suited when complex separations require greater peak capacity

 