This items is made to order and is not returnable and order cannot be canceled.

CUSTOM ITEM: HPLC Column, RP C18, 5um, 3.0mm ID x 100mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68518‑10P‑3 Cogent RP C18 HPLC Column is a durable, reversed‑phase column designed for reliable analytical separations, featuring 5 µm particles and fully double end‑capped C18 bonding.

Manufactured using high‑purity silica with traditional octadecylsilane (C18) chemistry, this stationary phase:

  • Uses complete end‑capping to minimize silanol interactions

  • Improves peak shape for polar and basic analytes

  • Provides consistent and reproducible chromatographic results

This column is ideal as a USP L1 alternate and as a dependable platform for routine and method development workflows.

100 mm Length – Increased Resolution

  • Higher resolving power compared to 50 mm columns

  • Improved separation of closely related compounds

  • Increased peak capacity for complex samples

  • Ideal when greater resolution is required without extended run times

3.0 mm ID – Solvent‑Saving Analytical Performance

  • Reduces mobile phase consumption vs 4.6 mm columns

  • Requires moderate flow rates with improved sensitivity vs 4.6 mm ID

  • Typical flow rate range: ~0.4–0.8 mL/min

  • Optimal starting range: ~0.5–0.7 mL/min

✅ Ideal for solvent savings and improved detection sensitivity ⚠️ Requires a system capable of stable, consistent reduced flow rates

Flow Rate & System Requirements (3.0 mm ID, 5 µm)

✅ Operates under standard high‑pressure HPLC conditions ✅ Produces lower backpressure than 3 µm and 1.8 µm columns, while remaining a high‑pressure column

Requires:

  • HPLC system capable of stable mid‑to‑low flow operation

  • Properly sized detector flow cell for reduced internal volume systems

⚠️ Systems must maintain accurate flow control at reduced flow rates for optimal performance.

Why Choose RP C18 (5 µm)

High‑Pressure Robustness & Reliability

  • Designed for standard high‑pressure HPLC systems

  • Lower backpressure relative to smaller particle sizes

  • Ideal for rugged, long‑lifetime analytical methods

Reliable Hydrophobic Retention

  • Strong reversed‑phase retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids

  • Provides greater retention than C8 phases

Method Development & USP Compatibility

  • Ideal for new method development

  • Suitable for USP L1 methods using 5 µm columns

  • Reliable alternate or replacement column

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Better performance for basic analytes

High Purity Silica

  • Consistent chromatographic performance

  • Reduced variability across runs

Durable & Cost‑Efficient

  • Longer column lifetime vs smaller particle sizes

  • Reduced system strain

  • Lower maintenance and replacement frequency

Typical Applications

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Method development and optimization

  • Routine analytical HPLC workflows

  • USP L1 reversed‑phase methods

Important Usage Notes

  • Operates under standard high‑pressure HPLC conditions

  • Requires systems capable of reliable reduced flow rates (3.0 mm ID)

  • Ideal for solvent‑saving analytical methods

  • Best used when balancing resolution, sensitivity, and solvent consumption

Made‑to‑Order & Pricing Information

This is a custom, made‑to‑order item.

  • Orders cannot be canceled once placed

  • Custom items are non‑returnable

Custom Order Item. Inquire for more information.

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media