HPLC Column, RP C18, 5um, 2.1mm ID x 100mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68518‑10P‑2 Cogent RP C18 HPLC Column is a durable, reversed‑phase column designed for reliable analytical separations, featuring 5 µm particles and fully double end‑capped C18 bonding.

Manufactured with high‑purity silica and traditional octadecylsilane (C18) chemistry, this stationary phase:

  • Uses complete end‑capping to minimize silanol interactions

  • Improves peak shape for polar and basic analytes

  • Provides consistent, reproducible chromatographic performance

This column is widely used as a USP L1 alternate column and for routine LC‑MS and analytical method development.

100 mm Length – Increased Resolution for LC‑MS

  • Higher resolving power compared to 50 mm columns

  • Improved separation of closely related compounds

  • Increased peak capacity for complex samples

  • Ideal for LC‑MS workflows requiring enhanced resolution

This format is commonly selected when greater separation is needed while maintaining reasonable run times.

Flow Rate & System Requirements (2.1 mm ID, 5 µm)

  • Typical flow rate range: ~0.2–0.5 mL/min

  • Optimal starting range: ~0.25–0.40 mL/min

  • Requires:

    • HPLC system capable of stable low‑flow delivery

    • Low‑volume detector flow cell

    • Reliable injection system

✅ Operates under standard high‑pressure HPLC conditions ✅ Generates lower backpressure than 3 µm and 1.8 µm columns, while remaining a high‑pressure analytical column

Why Choose RP C18 (5 µm)

High‑Pressure Robustness & Reliability

  • Designed for standard HPLC high‑pressure operation

  • Lower backpressure relative to smaller particle columns

  • Ideal for rugged, long‑lifetime analytical methods

Reliable Hydrophobic Retention

  • Strong retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids

  • Provides longer retention than C8 phases

Method Development & USP Compatibility

  • Ideal as a starting point for new methods

  • Suitable for USP L1 methods using 5 µm particles

  • Frequently used in LC‑MS where robustness is prioritized

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Better performance for basic analytes

High Purity Silica

  • Consistent chromatography

  • Excellent reproducibility

Durable & Cost‑Efficient

  • Longer column lifetime vs smaller particle sizes

  • Reduced system strain

  • Lower maintenance and replacement frequency

Typical Applications

  • LC‑MS analytical workflows

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Method development and optimization

  • USP L1 reversed‑phase methods

Important Usage Notes

  • Operates under standard high‑pressure HPLC conditions

  • Requires stable low‑flow system capability (2.1 mm ID)

  • Ideal for applications requiring increased resolution without UHPLC pressure demands

  • Preferred when robustness and reproducibility are more important than maximum efficiency

 