HPLC Column, RP C18, 5um, 4.6mm ID x 100mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68518‑10P Cogent RP C18 HPLC Column is a durable, reversed‑phase column engineered for reliable analytical performance, utilizing 5 µm particles and fully double end‑capped C18 bonding to deliver consistent retention, improved peak shape, and long column lifetime.

Manufactured using high‑purity silica with traditional octadecylsilane (C18) chemistry, this stationary phase:

  • Uses complete end‑capping to minimize silanol interactions

  • Improves peak shape for polar and basic analytes

  • Provides reproducible and robust chromatography

This column is ideal as a USP L1 alternate and a dependable choice for routine analytical methods and method development.

100 mm Length – Increased Resolution

  • Higher resolving power than 50 mm columns

  • Improved separation of closely related compounds

  • Increased peak capacity for complex mixtures

  • Ideal when shorter columns do not provide enough resolution

This configuration is commonly used when faster methods are needed but added resolution is required beyond a 50 mm column.

4.6 mm ID – Standard Analytical Performance

  • Industry‑standard HPLC column dimension

  • Compatible with all conventional HPLC systems

  • Typical flow rate range: ~0.8–1.5 mL/min

  • Optimal starting range: ~1.0–1.2 mL/min

Provides:

  • Strong detector response

  • Excellent reproducibility

  • Easy method transfer across systems

Flow Rate & System Requirements (4.6 mm ID, 5 µm)

✅ Operates under standard high‑pressure HPLC conditions ✅ Generates lower backpressure than 3 µm and 1.8 µm columns, while remaining a high‑pressure analytical column

  • Suitable for conventional HPLC systems

  • Tolerant of:

    • Higher flow rates

    • Viscous mobile phases

    • Extended analytical runs

Why Choose RP C18 (5 µm)

High‑Pressure Robustness & Reliability

  • Designed for standard high‑pressure HPLC systems

  • Lower backpressure relative to smaller particle columns

  • Ideal for rugged, long‑lifetime analytical workflows

Reliable Hydrophobic Retention

  • Strong retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids

  • Provides greater retention than C8 phases

Method Development & USP Compatibility

  • Ideal for new method development

  • Suitable for USP L1 methods using 5 µm particles

  • Reliable alternate or replacement column

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Better performance for basic analytes

High Purity Silica

  • Consistent chromatographic performance

  • Reduced variability across runs

Durable & Cost‑Efficient

  • Longer column lifetime vs smaller particle sizes

  • Reduced system strain

  • Lower maintenance and replacement frequency

Typical Applications

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Method development and optimization

  • Routine analytical HPLC workflows

  • USP L1 reversed‑phase methods

Important Usage Notes

  • Operates under standard high‑pressure HPLC conditions

  • Compatible with conventional analytical systems

  • Ideal for applications requiring improved resolution with maximum robustness

  • Preferred when reliability and system compatibility outweigh maximum efficiency

 