HPLC Column, RP C18, 5um, 4.6mm ID x 50mm Length, 100A. Cogent Brand. 1 EA.
Additional Info:
The 68518‑05P Cogent RP C18 HPLC Column is a durable, reversed‑phase column designed for reliable routine analysis and method development, featuring 5 µm particles and fully double end‑capped C18 bonding.
Manufactured using high‑purity silica with traditional octadecylsilane (C18) chemistry, this stationary phase provides:
Complete end‑capping to minimize silanol interactions
Improved peak shape for polar and basic analytes
Consistent and reproducible chromatographic performance
This column is ideal as a USP L1 alternate column and a trusted starting point for new analytical methods.
50 mm Length – Fast Analysis & Method Scouting
Designed for short run times and rapid separations
Lower backpressure compared to longer columns
Ideal for high‑throughput screening (HTS)
Frequently used as a scouting column for preparative method development
4.6 mm ID – Standard Analytical Performance
Industry‑standard HPLC column format
Compatible with all conventional HPLC systems
Typical flow rate range: ~0.8–1.5 mL/min
Optimal starting range: ~1.0–1.2 mL/min
Provides:
Strong detector response
Excellent reproducibility
Straightforward method transfer across laboratories
Flow Rate & System Requirements (4.6 mm ID, 5 µm)
✅ Operates under standard high‑pressure HPLC conditions ✅ Generates lower backpressure than 3 µm and 1.8 µm columns, but remains a high‑pressure analytical column
Suitable for conventional HPLC systems
More tolerant of:
Higher flow rates
Viscous mobile phases
Longer method durations
Why Choose RP C18 (5 µm)
High‑Pressure Robustness & Durability
Designed for standard HPLC high‑pressure operation
Lower backpressure relative to smaller particle columns
Ideal for rugged, long‑lifetime analytical methods
Reliable Hydrophobic Retention
Strong reversed‑phase retention for hydrophobic and neutral compounds
Excellent for long‑chain fatty acids
Provides longer retention than C8 phases
Method Development & USP Compatibility
Ideal as a starting point for new methods
Suitable for USP L1 methods using 5 µm particles
Commonly used for analytical to preparative method scouting
Cogent RP C18™ Advantages
Fully End‑Capped Surface
Minimizes secondary interactions
Improves peak symmetry
Better performance for basic analytes
High Purity Silica
Consistent analytical performance
Reduced variability between runs and columns
Durable & Cost‑Efficient
Longer column lifetime vs smaller particles
Reduced system strain
Lower maintenance and replacement frequency
Typical Applications
Pharmaceutical and QC analysis
Hydrophobic and neutral compound separations
Long‑chain fatty acids
Method development and optimization
Preparative method scouting
USP L1 reversed‑phase workflows
Important Usage Notes
Operates under standard high‑pressure HPLC conditions
Compatible with conventional analytical systems
Ideal for fast method development and screening workflows
Frequently used as a starting point before scale‑up to preparative columns