HPLC Column, RP C12, 5um, 2.1mm ID x 100mm Length, 100A. Cogent Brand. 1 EA.

Additional Information:

Cogent RP C12™ HPLC Columns are designed for reversed-phase separations requiring unique selectivity, rapid equilibration, and reproducible retention. The stationary phase is manufactured using a rigid adamantane-shaped carbon silane ligand bonded to ultra-high purity silica and fully double end capped to minimize secondary interactions. This distinctive bonded phase chemistry offers chromatographic behavior between traditional C8 and C18 phases, making it especially useful for complex mixtures, LC-MS methods, and analytical method development.

68512-10P-2 is packed with 5 µm RP C12™ particles featuring a 100 Å pore size in a 2.1 mm ID x 100 mm format. The narrow internal diameter provides reduced solvent consumption and excellent compatibility with LC-MS systems, while the 100 mm length offers increased resolving power compared to shorter columns. The RP C12™ phase typically provides less retention than C18 columns but greater retention than C8 columns for many hydrophobic compounds, offering an alternative selectivity profile that can improve challenging separations. The stationary phase is also compatible with highly aqueous mobile phases, including 100% water, without phase collapse or loss of retention.

The 2.1 mm ID x 100 mm format is frequently selected for LC-MS applications, method development, pharmaceutical analysis, and complex sample separations. Typical flow rates are approximately 0.2-0.3 mL/min. Standard HPLC systems used with 2.1 mm ID columns must be capable of delivering stable and reproducible low flow rates, and detector flow cells should be optimized for low-volume chromatography to achieve maximum performance.

Key Benefits

  • RP C12™ stationary phase

  • Adamantane-shaped bonded ligand

  • Fully double end capped

  • Ultra-high purity silica support

  • 100 Å pore size

  • Unique selectivity profile

  • Compatible with 100% aqueous mobile phases

  • Rapid column equilibration

  • Excellent for LC-MS applications

  • Low solvent consumption

Typical Applications

  • LC-MS methods

  • LC-MS/MS analysis

  • Reversed-phase HPLC

  • High-throughput screening (HTS)

  • Method development

  • Pharmaceutical analysis

  • Complex mixture separations

  • Quality control testing

  • Research and development

  • Hydrophobic compound analysis

Specifications

  • Product Type: HPLC Column

  • Stationary Phase: RP C12™

  • Chromatography Mode: Reversed Phase

  • Bonded Phase: Adamantane-Shaped C12 Ligand

  • Endcapping: Fully Double End Capped

  • Particle Size: 5 µm

  • Pore Size: 100 Å

  • Column Dimensions: 2.1 mm ID x 100 mm

  • Recommended Flow Rate: 0.2-0.3 mL/min

  • Column Hardware: Stainless Steel

  • Brand: Cogent

Important Notes

  • Provides a selectivity profile between traditional C8 and C18 phases

  • Compatible with highly aqueous and 100% water mobile phases

  • Rapid equilibration minimizes time between injections

  • 100 mm length provides improved resolution and peak capacity

  • Excellent choice for LC-MS and LC-MS/MS methods

  • Useful for complex mixtures requiring alternative selectivity

  • 2.1 mm ID format minimizes solvent consumption and improves MS compatibility

  • Requires an HPLC system capable of reliable low-flow operation at approximately 0.2-0.3 mL/min

  • Best performance is achieved using low-volume detector flow cells and LC-MS interfaces


 