CUSTOM ITEM: HPLC Column, RP C18, 3um, 4.0mm ID x 150mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68318‑15P‑4 Cogent RP C18 HPLC Column is designed for maximum‑resolution analytical separations while maintaining reduced solvent consumption, using 3 µm particles and fully double end‑capped C18 bonding to deliver consistent retention, improved efficiency, and dependable results.

Manufactured using high‑purity silica and traditional octadecylsilane (C18) chemistry, this stationary phase:

  • Uses complete end‑capping to minimize silanol interactions

  • Improves peak shape for polar and basic analytes

  • Provides excellent reproducibility and robustness

This column is well suited as both a primary analytical column and an alternate for USP L1 methods requiring 3 µm particle phases.

150 mm Length – Maximum Resolution

  • Highest resolving power within the 4.0 mm RP C18 range

  • Maximizes peak capacity for complex mixtures

  • Ideal for closely related compounds and difficult separations

  • Best suited when maximum resolution is required over speed

  • Longer run times compared to 50 mm and 100 mm formats

4.0 mm ID – Solvent‑Saving Analytical Performance

  • Comparable performance to 4.6 mm ID analytical columns

  • Reduced mobile phase consumption and waste

  • Typical flow rate range: ~0.8–1.2 mL/min

  • Optimal starting range: ~0.85–1.10 mL/min

Benefits:

  • Lower operating costs

  • Reduced solvent usage

  • Compatible with standard HPLC systems

Why Choose RP C18 (3 µm)

Balanced Efficiency & Pressure

  • Higher efficiency than 5 µm columns

  • Lower backpressure than sub‑2 µm UHPLC columns

  • Ideal balance between performance and system compatibility

Reliable Hydrophobic Retention

  • Strong reversed‑phase retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids and similar analytes

USP Method Compatibility

  • Suitable for USP L1 methods using 3 µm stationary phases

  • Effective alternate or replacement column

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Enhances performance for basic analytes

High Purity Silica

  • Consistent results across runs

  • Reduced variability and improved reliability

Cost‑Efficient Operation

  • Lower pressure requirements vs UHPLC columns

  • Reduced solvent consumption vs larger ID columns

  • Lower cost per analysis

Typical Applications

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Method development and validation

  • Complex analytical workflows

  • USP L1 reversed‑phase methods

Important Usage Notes

  • Compatible with standard HPLC systems

  • Monitor pressure when using long gradients or viscous mobile phases

  • Ideal when maximum resolution is required without UHPLC systems

  • Best suited for complex separations where shorter columns are insufficient

Made‑to‑Order & Pricing Information

This is a custom, made‑to‑order item.

  • Orders cannot be canceled once placed

  • Custom items are non‑returnable

Custom Order Item. Inquire for more information.