HPLC Column, RP C18, Wide Pore, 3um, 2.1mm ID x 150mm Length, 300A. Cogent Brand. 1 EA.

Additional Info:

The 68318‑15P‑2‑3M Cogent RP C18 Wide Pore HPLC Column is designed for maximum‑resolution separations of large molecular weight analytes, combining 3 µm particles with a 300 Å wide‑pore structure to deliver superior access, retention, and peak shape for biomolecules.

Manufactured using high‑purity silica and traditional octadecylsilane (C18) bonding, and fully double end‑capped, this phase provides:

  • Reduced silanol interactions

  • Improved peak symmetry for proteins, peptides, and large polar analytes

  • Excellent reproducibility and robustness

The 300 Å pore size enables large molecules to fully access the stationary phase, eliminating steric hindrance often seen in standard 100 Å columns.

150 mm Length – Maximum Resolution for Biomolecules

  • Highest resolving power in the 2.1 mm wide‑pore C18 range

  • Maximizes peak capacity for complex biomolecule mixtures

  • Ideal for proteins, peptides, and closely related macromolecules

  • Preferred for LC‑MS workflows requiring detailed separation

  • Longer run times compared to 50 mm and 100 mm formats

This column is best suited when maximum separation and purity are required over speed.

Flow Rate & System Requirements (2.1 mm ID, 3 µm, 300 Å)

  • Typical flow rate range: ~0.2–0.4 mL/min

  • Optimal starting range: ~0.18–0.30 mL/min for maximum resolution

  • Requires:

    • HPLC or LC‑MS system capable of stable low‑flow delivery

    • Low‑volume detector flow cell for optimal sensitivity

    • Precision injection system

⚠️ Standard HPLC systems are compatible but must maintain consistent low‑flow control. ⚠️ Monitor pressure when using viscous solvents and long gradients.

Why Choose Wide Pore (300 Å) C18

Designed for Large Molecules

  • Enables separation of:

    • Proteins

    • Peptides

    • Oligonucleotides

  • Eliminates restricted diffusion seen in 100 Å columns

Improved Recovery & Peak Shape

  • Better analyte interaction with stationary phase

  • Improved peak symmetry and reproducibility for high molecular weight compounds

Maintains Reversed‑Phase Selectivity

  • Retains classic C18 hydrophobic retention behavior

  • Suitable for lipids and long‑chain fatty acids

RP C18 (3 µm) Performance Advantages

Balanced Efficiency & Pressure

  • More efficient than 5 µm columns

  • Lower backpressure than 1.8 µm UHPLC columns

  • Ideal balance between performance and system compatibility

USP Method Compatibility

  • Suitable for USP L1 methods adapted for large molecule separations

  • Strong alternative for wide‑pore reversed‑phase methods

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Enhances performance for polar and basic analytes

High Purity Silica

  • Consistent chromatographic performance

  • Reduced run‑to‑run variation

Cost‑Efficient Operation

  • Lower pressure vs UHPLC columns

  • Reduced solvent consumption with 2.1 mm format

  • Lower cost per analysis

Typical Applications

  • Protein and peptide separations

  • Oligonucleotide analysis

  • Biomolecule LC‑MS workflows

  • Lipids and hydrophobic compounds

  • Long‑chain fatty acids

  • Complex biomolecule mixtures requiring maximum resolution

Important Usage Notes

  • Designed for large molecule separations using 300 Å pore media

  • Requires stable low‑flow analytical system capability

  • Ideal when 100 Å columns limit analyte access or separation

  • Optimize temperature and mobile phase conditions for best biomolecule performance

 