HPLC Column, RP C18, 3um, 4.6mm ID x 150mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68318‑15P Cogent RP C18 HPLC Column is engineered for maximum‑resolution analytical separations, featuring 3 µm particles and fully double end‑capped C18 bonding to provide high efficiency, excellent peak shape, and consistent performance.

Manufactured using high‑purity silica with traditional octadecylsilane (C18) chemistry, this stationary phase offers:

  • Complete end‑capping to minimize silanol interactions

  • Improved peak shape for polar and basic analytes

  • Robust and reproducible performance across applications

This column is widely used as a primary analytical column and as a USP L1 alternate, trusted for both routine and advanced method development.

150 mm Length – Maximum Resolution & Peak Capacity

  • Highest resolving power in the 4.6 mm RP C18 column range

  • Maximizes separation of closely related compounds

  • Ideal for complex mixtures and demanding analytical methods

  • Preferred when maximum resolution is required over speed

  • Longer run times compared to 50 mm and 100 mm formats

4.6 mm ID – Standard Analytical Performance

  • Industry‑standard HPLC column dimension

  • Compatible with all conventional HPLC systems

  • Typical flow rate range: ~0.8–1.5 mL/min

  • Optimal starting range: ~1.0–1.2 mL/min

Provides:

  • Strong detector response

  • Excellent reproducibility

  • Easy method transfer between instruments

Why Choose RP C18 (3 µm)

Balanced Efficiency & Pressure

  • More efficient than 5 µm columns

  • Lower backpressure than 1.8 µm UHPLC columns

  • Ideal balance between performance and system compatibility

Reliable Hydrophobic Retention

  • Strong retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids and similar analytes

Versatile Method Development

  • Suitable for new method development

  • Widely used across industries

  • Compatible with USP L1 method substitution

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Enhances performance for basic compounds

High Carbon Load

  • Increased retention and loading capacity

  • Greater method flexibility

Low Column Bleed

  • Ideal for sensitive detection techniques (LC‑MS and UV)

  • Clean baselines and accurate results

High Purity Silica

  • Consistent, reproducible chromatography

  • Reduced variability between columns and runs

Typical Applications

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Complex mixture separations

  • Method development and validation

  • USP L1 reversed‑phase methods

Important Usage Notes

  • Compatible with standard HPLC systems

  • Monitor pressure for viscous solvents or extended methods

  • Ideal when maximum resolution is required

  • Best suited for complex separations where shorter columns are insufficient

 

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media