CUSTOM ITEM: HPLC Column, RP C18, 3um, 4.0mm ID x 100mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68318‑10P‑4 Cogent RP C18 HPLC Column is a high‑performance, solvent‑saving reversed‑phase column featuring 3 µm particles and fully double end‑capped C18 bonding, providing improved efficiency, consistent retention, and reliable analytical results.

Manufactured with high‑purity silica and traditional octadecylsilane (C18) chemistry, this stationary phase:

  • Uses complete end‑capping to minimize silanol interactions

  • Improves peak shape for polar and basic analytes

  • Provides excellent reproducibility and robustness

This column is ideal as both a primary analytical column and as an alternate for USP L1 methods requiring 3 µm particle columns.

100 mm Length – Increased Resolution

  • Higher resolving power compared to 50 mm columns

  • Improved peak capacity and separation of closely related analytes

  • Ideal when short columns do not provide sufficient resolution

  • Balanced performance between analysis time and separation quality

4.0 mm ID – Solvent‑Saving Analytical Performance

  • Comparable performance to 4.6 mm ID columns

  • Reduced mobile phase consumption and waste

  • Typical flow rate range: ~0.8–1.2 mL/min

  • Optimal starting range: ~0.9–1.1 mL/min

Benefits:

  • Lower operating cost

  • Maintains strong detector response

  • Compatible with standard HPLC systems

Why Choose RP C18 (3 µm)

Balanced Efficiency & Pressure

  • Higher efficiency than 5 µm columns

  • Lower backpressure than sub‑2 µm UHPLC columns

  • Ideal balance of performance and system compatibility

Reliable Hydrophobic Retention

  • Strong reversed‑phase retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids and similar analytes

USP Method Compatibility

  • Suitable for USP L1 methods using 3 µm phases

  • Valuable as an alternate or replacement column

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Reduces secondary interactions

  • Improves peak symmetry

  • Better performance for basic analytes

High Purity Silica

  • Consistent results across runs

  • Reduced variability between columns

Cost‑Efficient Operation

  • Lower pressure requirements than UHPLC columns

  • Reduced solvent consumption vs larger ID columns

  • Lower cost per analysis

Typical Applications

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Method development and validation

  • Routine reversed‑phase HPLC workflows

  • USP L1 analytical methods

Important Usage Notes

  • Compatible with standard HPLC systems

  • Monitor pressure when using viscous solvents or extended run conditions

  • Ideal for applications requiring improved resolution without UHPLC systems

  • Suitable for routine and development workflows