HPLC Column, RP C18, Wide Pore, 3um, 2.1mm ID x 100mm Length, 300A. Cogent Brand. 1 EA.

Additional Info:

The 68318‑10P‑2‑3M Cogent RP C18 Wide Pore HPLC Column is engineered for enhanced separation of large molecular weight analytes, combining 3 µm particle size with a 300 Å pore structure to maximize analyte accessibility and chromatographic performance.

This stationary phase is produced using high‑purity silica with traditional octadecylsilane (C18) bonding, and features full double end‑capping, delivering:

  • Reduced silanol activity

  • Improved peak shape for large, polar, and biomolecular analytes

  • Excellent reproducibility and robustness

The 300 Å wide‑pore design allows large molecules to fully access the stationary phase, eliminating steric limitations common with standard 100 Å columns.

100 mm Length – Increased Resolution for Biomolecules

  • Higher resolving power than 50 mm columns

  • Improved separation of peptides, proteins, and large analytes

  • Increased peak capacity for complex mixtures

  • Ideal for LC‑MS workflows requiring enhanced resolution

This format is preferred when greater separation is required without the longer run times of 150 mm columns.

Flow Rate & System Requirements (2.1 mm ID, 3 µm, 300 Å)

  • Typical flow rate range: ~0.2–0.4 mL/min

  • Optimal starting range: ~0.25–0.35 mL/min

  • Requires:

    • HPLC or LC‑MS system capable of stable low‑flow delivery

    • Low‑volume detector flow cell

    • Precision injection system

⚠️ Standard HPLC systems are acceptable but must be capable of consistent low‑flow operation for optimal performance.

Why Choose Wide Pore (300 Å) C18

Designed for Large Molecules

  • Allows access for:

    • Proteins

    • Peptides

    • Oligonucleotides

  • Eliminates restricted diffusion seen in 100 Å columns

Improved Recovery & Peak Shape

  • Enhanced analyte interaction with stationary phase

  • Improved peak symmetry and reproducibility for biomolecules

Maintains Reversed‑Phase Selectivity

  • Retains classic C18 hydrophobic interaction behavior

  • Suitable for lipids and long‑chain fatty acids

RP C18 (3 µm) Performance Advantages

Balanced Efficiency & Pressure

  • Higher efficiency than 5 µm columns

  • Lower backpressure than 1.8 µm UHPLC columns

  • Ideal for standard HPLC and LC‑MS systems

USP Method Compatibility

  • Suitable for USP L1 methods adapted for large molecules

  • Reliable alternate column option

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Reduces secondary interactions

  • Improves peak symmetry

  • Better performance for polar and basic analytes

High Purity Silica

  • Consistent chromatography

  • Reduced run‑to‑run variability

Cost‑Efficient Operation

  • Lower pressure vs UHPLC columns

  • Reduced solvent consumption with 2.1 mm ID

  • Lower cost per analysis

Typical Applications

  • Protein and peptide separations

  • Oligonucleotide analysis

  • Biomolecule LC‑MS workflows

  • Lipids and hydrophobic analytes

  • Long‑chain fatty acids

  • Methods requiring wide‑pore reversed‑phase chromatography

Important Usage Notes

  • Designed for large molecule separations (300 Å pore size)

  • Requires stable low‑flow analytical system performance

  • Ideal when 100 Å columns limit analyte access or resolution

  • Optimize temperature and mobile phase for best biomolecule performance

 

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media