HPLC Column, RP C18, Wide Pore, 3um, 2.1mm ID x 100mm Length, 300A. Cogent Brand. 1 EA.
Additional Info:
The 68318‑10P‑2‑3M Cogent RP C18 Wide Pore HPLC Column is engineered for enhanced separation of large molecular weight analytes, combining 3 µm particle size with a 300 Å pore structure to maximize analyte accessibility and chromatographic performance.
This stationary phase is produced using high‑purity silica with traditional octadecylsilane (C18) bonding, and features full double end‑capping, delivering:
Reduced silanol activity
Improved peak shape for large, polar, and biomolecular analytes
Excellent reproducibility and robustness
The 300 Å wide‑pore design allows large molecules to fully access the stationary phase, eliminating steric limitations common with standard 100 Å columns.
100 mm Length – Increased Resolution for Biomolecules
Higher resolving power than 50 mm columns
Improved separation of peptides, proteins, and large analytes
Increased peak capacity for complex mixtures
Ideal for LC‑MS workflows requiring enhanced resolution
This format is preferred when greater separation is required without the longer run times of 150 mm columns.
Flow Rate & System Requirements (2.1 mm ID, 3 µm, 300 Å)
Typical flow rate range: ~0.2–0.4 mL/min
Optimal starting range: ~0.25–0.35 mL/min
Requires:
HPLC or LC‑MS system capable of stable low‑flow delivery
Low‑volume detector flow cell
Precision injection system
⚠️ Standard HPLC systems are acceptable but must be capable of consistent low‑flow operation for optimal performance.
Why Choose Wide Pore (300 Å) C18
Designed for Large Molecules
Allows access for:
Proteins
Peptides
Oligonucleotides
Eliminates restricted diffusion seen in 100 Å columns
Improved Recovery & Peak Shape
Enhanced analyte interaction with stationary phase
Improved peak symmetry and reproducibility for biomolecules
Maintains Reversed‑Phase Selectivity
Retains classic C18 hydrophobic interaction behavior
Suitable for lipids and long‑chain fatty acids
RP C18 (3 µm) Performance Advantages
Balanced Efficiency & Pressure
Higher efficiency than 5 µm columns
Lower backpressure than 1.8 µm UHPLC columns
Ideal for standard HPLC and LC‑MS systems
USP Method Compatibility
Suitable for USP L1 methods adapted for large molecules
Reliable alternate column option
Cogent RP C18™ Advantages
Fully End‑Capped Surface
Reduces secondary interactions
Improves peak symmetry
Better performance for polar and basic analytes
High Purity Silica
Consistent chromatography
Reduced run‑to‑run variability
Cost‑Efficient Operation
Lower pressure vs UHPLC columns
Reduced solvent consumption with 2.1 mm ID
Lower cost per analysis
Typical Applications
Protein and peptide separations
Oligonucleotide analysis
Biomolecule LC‑MS workflows
Lipids and hydrophobic analytes
Long‑chain fatty acids
Methods requiring wide‑pore reversed‑phase chromatography
Important Usage Notes
Designed for large molecule separations (300 Å pore size)
Requires stable low‑flow analytical system performance
Ideal when 100 Å columns limit analyte access or resolution
Optimize temperature and mobile phase for best biomolecule performance