HPLC Column, RP C18, 3um, 2.1mm ID x 100mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68318‑10P‑2 Cogent RP C18 HPLC Column delivers premium, balanced performance using 3 µm particles and fully double end‑capped C18 bonding, providing high efficiency, excellent peak shape, and reliable reproducibility.

Manufactured with high‑purity silica and traditional octadecylsilane (C18) bonding, this stationary phase:

  • Uses complete end‑capping to minimize silanol activity

  • Improves peak shape for polar and basic analytes

  • Provides excellent lot‑to‑lot reproducibility

This column is an ideal choice as an alternate for USP L1 methods and as a dependable platform for new method development.

100 mm Length – Increased Resolution for LC‑MS

  • Higher resolving power compared to 50 mm columns

  • Improved peak capacity and separation of closely related analytes

  • Ideal for LC‑MS workflows requiring enhanced resolution

  • Balanced performance between analysis time and separation quality

This format is commonly selected when greater separation is needed without moving to longer (150 mm) columns.

Flow Rate & System Requirements (2.1 mm ID, 3 µm)

  • Typical flow rate range: ~0.2–0.4 mL/min

  • Optimal starting range: ~0.25–0.35 mL/min

  • Requires:

    • HPLC system capable of stable low‑flow delivery

    • Low‑volume detector flow cell for optimal sensitivity

    • Accurate injection system

⚠️ Standard HPLC systems are generally compatible but must be capable of consistent low‑flow operation.

Why Choose RP C18 (3 µm)

Balanced Efficiency & Pressure

  • More efficient than 5 µm columns

  • Lower backpressure than sub‑2 µm UHPLC columns

  • Ideal balance of performance and system compatibility

Reliable Hydrophobic Retention

  • Strong retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids and similar analytes

Versatile Method Development

  • Highly adaptable across different methods

  • Common first‑choice column for new methods

  • Suitable for USP L1 method substitution

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Enhances performance for basic compounds

High Carbon Load

  • Increased retention and loading capacity

  • Improved robustness across diverse analytes

Low Column Bleed

  • Ideal for sensitive detection methods (LC‑MS)

  • Cleaner baselines and more accurate data

High Purity Silica

  • Consistent, reproducible results

  • Reduced variability between runs and batches

Typical Applications

  • LC‑MS analytical workflows

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Method development and optimization

  • USP L1 reversed‑phase methods

Important Usage Notes

  • Designed for low‑flow (2.1 mm) analytical methods

  • Requires stable low‑flow system performance

  • Ideal when increased resolution is needed without UHPLC pressure requirements

  • Common choice for LC‑MS applications requiring higher separation power

 