HPLC Column, RP C18, 3um, 4.6mm ID x 100mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68318‑10P Cogent RP C18 HPLC Column is a trusted, high‑value reversed‑phase column featuring 3 µm particles and fully double end‑capped C18 bonding, providing improved efficiency, strong retention, and consistent analytical performance.

Manufactured using high‑purity silica with traditional octadecylsilane (C18) bonding, this stationary phase:

  • Uses complete end‑capping to minimize silanol activity

  • Improves peak shape for polar and basic analytes

  • Provides reliable and reproducible chromatography

This column is widely used as a primary analytical column, as well as an alternate for USP L1 classified methods requiring 3 µm stationary phases.

100 mm Length – Increased Resolution

  • Higher resolving power compared to 50 mm columns

  • Improved separation of closely related compounds

  • Ideal when short columns do not provide sufficient resolution

  • Balanced performance between run time and separation quality

This format is commonly selected when faster methods are needed but 50 mm columns cannot achieve required resolution.

4.6 mm ID – Standard Analytical Performance

  • Industry‑standard HPLC column dimension

  • Compatible with all conventional HPLC systems

  • Typical flow rate range: ~0.8–1.5 mL/min

  • Optimal starting range: ~1.0–1.2 mL/min

Provides:

  • Strong detector response

  • Excellent reproducibility

  • Easy method transfer between systems

Why Choose RP C18 (3 µm)

Balanced Efficiency & Pressure

  • More efficient than 5 µm columns

  • Lower backpressure than sub‑2 µm UHPLC columns

  • Ideal balance between performance and system compatibility

Reliable Hydrophobic Retention

  • Strong reversed‑phase retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids and similar analytes

Method Development Versatility

  • Ideal for new method development

  • Compatible with a wide range of analytical methods

  • Suitable for USP L1 method substitution

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Better performance for basic compounds

High Purity Silica

  • Consistent, reproducible chromatography

  • Reduced variability between runs and columns

Cost‑Efficient Operation

  • Lower pressure requirements vs UHPLC columns

  • Reduced solvent usage vs longer column formats

  • Lower cost per analysis

Typical Applications

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Method development and validation

  • Routine analytical HPLC workflows

  • USP L1 reversed‑phase methods

Important Usage Notes

  • Compatible with standard HPLC systems

  • Monitor system pressure when using viscous solvents or extended methods

  • Ideal for applications requiring improved resolution over short columns

  • A strong choice when balancing speed, performance, and system compatibility

 

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media