CUSTOM ITEM: HPLC Column, RP C18, Wide Pore, 3um, 4.0mm ID x 50mm Length, 300A. Cogent Brand. 1 EA.

Additional Info:

The 68318‑05P‑4‑3M Cogent RP C18 Wide Pore HPLC Column is a high‑value reversed‑phase column specifically designed for large molecules and biomolecules, combining 3 µm particle size with a 300 Å pore structure for optimal analyte accessibility.

This stationary phase is manufactured with high‑purity silica and traditional octadecylsilane (C18) bonding, with complete double end‑capping, providing:

  • Reduced silanol interactions

  • Improved peak shape for proteins and large polar analytes

  • Consistent and reproducible performance

The wide‑pore (300 Å) design allows larger molecules to fully access the stationary phase, improving retention and recovery compared to standard 100 Å columns.

50 mm Length – Fast Biomolecule Analysis

  • Optimized for rapid separations and short run times

  • Lower backpressure than longer columns

  • Ideal for screening and high‑throughput workflows

  • Excellent for method development of biomolecules

4.0 mm ID – Solvent‑Saving Analytical Performance

  • Comparable chromatographic behavior to 4.6 mm ID columns

  • Reduced mobile phase consumption

  • Typical flow rate range: ~0.8–1.2 mL/min

  • Optimal starting range: ~0.9–1.1 mL/min

Benefits:

  • Lower operating cost

  • Reduced solvent waste

  • Compatible with standard HPLC systems

Why Choose Wide Pore (300 Å) C18

Designed for Large Molecules

  • Provides access to the stationary phase for:

    • Proteins

    • Peptides

    • Oligonucleotides

  • Prevents steric exclusion seen in 100 Å phases

Improved Recovery & Reproducibility

  • Better analyte interaction with the stationary phase

  • Improved peak shapes for large molecular weight compounds

Maintains Reversed‑Phase Selectivity

  • Retains hydrophobic interaction behavior

  • Suitable for lipids and long‑chain fatty acids

RP C18 (3 µm) Performance Advantages

Balanced Efficiency & Pressure

  • More efficient than 5 µm columns

  • Lower backpressure than sub‑2 µm UHPLC columns

  • Allows use on standard HPLC systems

USP Method Compatibility

  • Suitable for USP L1 methods (large molecule adaptation)

  • Ideal alternate column for wide‑pore requirements

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Improved peak symmetry

  • Reduced secondary interactions

High Purity Silica

  • Consistent performance across runs

  • Reduced variability

Cost‑Efficient Operation

  • Lower pressure requirements than UHPLC columns

  • Reduced solvent consumption vs 4.6 mm ID formats

Typical Applications

  • Protein and peptide separations

  • Oligonucleotide analysis

  • Large biomolecule chromatography

  • Lipids and hydrophobic compounds

  • Long‑chain fatty acids

  • Methods requiring wide‑pore reversed‑phase columns

Important Usage Notes

  • Designed for large molecule separations using wide‑pore media

  • Compatible with standard HPLC systems

  • Optimize temperature and mobile phase for best biomolecule performance

  • Ideal for applications where 100 Å columns limit analyte access

Made‑to‑Order & Pricing Information

This is a custom, made‑to‑order item.

  • Orders cannot be canceled once placed

  • Custom items are non‑returnable

Custom Order Item. Inquire for more information.