This items is made to order and is not returnable and order cannot be canceled.

CUSTOM ITEM: HPLC Column, RP C18, 3um, 4.0mm ID x 50mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68318‑05P‑4 Cogent RP C18 HPLC Column is a high‑value, fully end‑capped reversed‑phase column designed to deliver consistent retention, improved efficiency, and reliable performance for a wide range of analytical methods.

Manufactured with high‑purity silica and traditional octadecylsilane (C18) bonding, this stationary phase:

  • Uses full double end‑capping to minimize silanol interactions

  • Improves peak shape for polar and basic analytes

  • Provides excellent reproducibility across methods

This column is widely used as both a primary analytical column and as an alternate choice for USP L1 methods using 3 µm particle columns.

50 mm Length – Fast Analysis & Throughput

  • Designed for short run times and rapid separations

  • Lower backpressure compared to longer columns

  • Ideal for high‑throughput workflows and screening

  • Efficient for method development and optimization

4.0 mm ID – Solvent‑Saving Analytical Performance

  • Provides performance similar to 4.6 mm ID columns

  • Reduces mobile phase consumption and waste

  • Typical flow rate range: ~0.8–1.2 mL/min

  • Optimal starting range: ~0.9–1.1 mL/min

Benefits:

  • Lower operating cost compared to 4.6 mm columns

  • Maintains strong detector response

  • Compatible with standard HPLC systems

Why Choose RP C18 (3 µm)

Balanced Efficiency & Pressure

  • Higher efficiency than 5 µm columns

  • Lower backpressure than sub‑2 µm UHPLC columns

  • Ideal balance between performance and system compatibility

Reliable Hydrophobic Retention

  • Strong reversed‑phase retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids and similar analytes

USP Method Compatibility

  • Suitable for USP L1 methods requiring 3 µm particles

  • Valuable as an alternate or replacement column

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Reduces secondary interactions

  • Improves peak symmetry

  • Better performance for basic compounds

High Purity Silica

  • Consistent chromatography

  • Reduced variability between runs

Cost‑Efficient Operation

  • Lower solvent usage vs larger ID columns

  • Reduced pressure demands vs UHPLC columns

  • Lower cost per analysis

Typical Applications

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Method development and validation

  • Routine reversed‑phase HPLC workflows

  • USP L1 analytical methods

Important Usage Notes

  • Compatible with standard HPLC systems

  • Monitor pressure when using viscous solvents or longer methods

  • Ideal balance between efficiency and system compatibility

  • Recommended for labs seeking reliable performance with reduced solvent use

Made‑to‑Order & Pricing Information

This is a custom, made‑to‑order item.

  • Orders cannot be canceled once placed

  • Custom items are non‑returnable

Custom Order Item. Inquire for more information.