HPLC Column, RP C18, 3um, 2.1mm ID x 50mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

The 68318‑05P‑2 Cogent RP C18 HPLC Column is a high‑value, high‑performance reversed‑phase column featuring 3 µm particles and fully double end‑capped C18 bonding, delivering reliable retention, improved efficiency, and consistent chromatographic performance.

Manufactured using high‑purity silica with traditional octadecylsilane (C18) bonding, this column:

  • Uses complete end‑capping to minimize silanol interactions

  • Improves peak shape for polar and basic analytes

  • Provides consistent and reproducible separations

This column is ideal both as a primary method development tool and as an alternate column for USP L1 methods using 3 µm particles.

50 mm Length – Speed & Throughput

  • Designed for fast separations and short run times

  • Lower backpressure compared to longer columns

  • Ideal for high‑throughput screening and method development

  • Excellent for LC‑MS workflows requiring rapid analysis

Flow Rate & System Requirements (2.1 mm ID, 3 µm)

  • Typical flow rate range: ~0.2–0.4 mL/min

  • Optimal starting range: ~0.25–0.35 mL/min

  • Requires:

    • HPLC system capable of stable low‑flow delivery

    • Low‑volume detector flow cell

    • Accurate injection system

⚠️ While compatible with standard HPLC systems, longer columns or viscous mobile phases may increase backpressure.

Why Choose RP C18 (3 µm)

Balanced Efficiency & Pressure

  • Higher efficiency than 5 µm columns

  • Lower backpressure than sub‑2 µm UHPLC columns

  • Ideal balance between performance and system compatibility

Reliable Hydrophobic Retention

  • Strong reversed‑phase retention for hydrophobic and neutral compounds

  • Excellent for long‑chain fatty acids and similar analytes

USP Method Compatibility

  • Suitable for USP L1 methods with 3 µm specifications

  • Excellent alternate column option

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Reduces secondary interactions

  • Improves peak symmetry

  • Better performance for basic compounds

High Purity Silica

  • Consistent, reproducible chromatography

  • Reduced batch‑to‑batch variation

Cost‑Efficient Operation

  • Lower pressure vs UHPLC columns

  • Compatible with a wider range of systems

  • Lower cost per analysis

Typical Applications

  • LC‑MS analytical workflows

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Long‑chain fatty acids

  • Method development and validation

  • USP L1 method applications

Important Usage Notes

  • Designed for low‑flow (2.1 mm) analytical methods

  • Requires stable low‑flow system performance

  • Monitor pressure for viscous solvents or longer column methods

  • Ideal balance between efficiency and instrument compatibility

 