UHPLC Column, RP C18, 1.8um, 100A. 2.1mm ID x 150mm Length. Cogent Brand. 1 EA.

Additional Info:

The 68118‑15P‑2 Cogent RP C18 UHPLC Column is engineered for maximum resolution and peak capacity, using 1.8 µm particles and fully double end‑capped C18 bonding to deliver high‑efficiency, reproducible separations.

Manufactured with high‑purity silica and traditional octadecylsilane (C18) bonding, this column provides:

  • Complete end‑capping to reduce silanol activity

  • Improved peak symmetry for polar and basic analytes

  • High reproducibility and method robustness

This column is ideal for complex separations where maximum resolving power is required.

150 mm Length – Maximum Resolution for LC‑MS

  • Highest resolving power in the 2.1 mm RP C18 range

  • Maximizes peak capacity and separation of complex mixtures

  • Ideal for samples with a large number of peaks and diverse compounds

  • Preferred for LC‑MS workflows requiring detailed resolution

  • Longer run times compared to 50 mm and 100 mm formats

This format is commonly used when maximum analytical performance outweighs speed.

Flow Rate & System Requirements (2.1 mm ID, 1.8 µm)

⚠️ Requires UHPLC system capability due to high backpressure

  • Typical flow rate range: ~0.2–0.4 mL/min

  • Optimal starting range: ~0.18–0.30 mL/min for maximum resolution

  • Requires:

    • UHPLC system capable of high‑pressure operation

    • Low‑volume detector flow cell

    • Accurate and stable low‑flow pumping

✅ Sample preparation requirement: use a 0.2 µm syringe filter to prevent clogging and maintain column performance

⚠️ Standard HPLC systems may not support required pressures or low‑flow precision.

Why Choose RP C18 for UHPLC

Maximum Efficiency & Peak Capacity

  • 1.8 µm particles deliver exceptional plate counts

  • Highest peak capacity among standard particle sizes

  • Ideal for resolving complex, multi‑component samples

Reliable Hydrophobic Retention

  • Strong retention for hydrophobic and neutral compounds

  • Predictable reversed‑phase chromatographic behavior

Versatile Method Development Platform

  • Widely applicable across industries

  • Ideal for new method development and optimization

  • Easily scaled to different column lengths and IDs

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Reduced secondary interactions

  • Improved peak symmetry

  • Better performance for basic compounds

High Purity Silica

  • Consistent and reproducible results

  • Reduced column‑to‑column variability

Efficient UHPLC Operation

  • Higher throughput despite longer column length

  • Improved resolution without sacrificing method reliability

  • Reduced solvent consumption with 2.1 mm format

Typical Applications

  • LC‑MS workflows requiring maximum resolution

  • Pharmaceutical and bioanalytical analysis

  • Complex mixture separations

  • Hydrophobic and neutral compound analysis

  • Method development for challenging analytes

Important Usage Notes

  • Requires UHPLC system capable of high pressure

  • Use 0.2 µm filtration to protect column lifetime

  • Ideal for high‑complexity separations with many analytes

  • Best suited when maximum resolution is required over speed

 