UHPLC Column, RP C18, 1.8um, 100A. 4.6mm ID x 100mm Length. Cogent Brand. 1 EA.
Additional Info:
The 68118‑10P Cogent RP C18 UHPLC Column is a high‑efficiency reversed‑phase column featuring 1.8 µm particles and fully double end‑capped C18 bonding, delivering enhanced resolution, strong retention, and reliable chromatographic performance.
Manufactured with high‑purity silica and traditional octadecylsilane bonding, this column offers:
Complete end‑capping to minimize silanol activity
Improved peak shape for polar and basic analytes
High reproducibility for routine and advanced analytical work
This column is a trusted option for method development and routine UHPLC applications, offering consistent, predictable results.
100 mm Length – Increased Resolution
Higher resolving power than 50 mm columns
Improved separation of closely related compounds
Ideal when 50 mm columns do not provide sufficient resolution
Balanced performance between speed and separation quality
This configuration is commonly used when greater resolution is required without the longer run times of 150 mm columns.
Flow Rate & System Requirements (4.6 mm ID, 1.8 µm)
⚠️ Requires UHPLC system capability due to increased backpressure
Typical flow rate range: ~1.0–2.0 mL/min
Optimal starting range: ~1.2–1.5 mL/min
Requires:
UHPLC system capable of high‑pressure operation
Standard flow detector compatible with 4.6 mm ID
Stable high‑flow pumping capability
✅ Sample preparation requirement: filter samples using a 0.2 µm syringe filter prior to injection to protect the column.
Why Choose RP C18 for UHPLC
High Efficiency & Resolution
1.8 µm particles provide maximum plate count and peak capacity
Significantly better performance than 3 µm+ columns
Enables resolution improvements without drastically increasing run time
Reliable Hydrophobic Retention
Strong, predictable reversed‑phase behavior
Ideal for hydrophobic and neutral compounds
Versatile Method Development Platform
Widely applicable across industries
Excellent starting point for new method development
Easily scalable across column dimensions
Cogent RP C18™ Advantages
Fully End‑Capped Surface
Minimizes secondary interactions
Improves peak symmetry
Better performance for basic analytes
High Purity Silica
Consistent column‑to‑column performance
Improved analytical reproducibility
Cost‑Efficient Operation
Reduced solvent usage compared to longer columns
Increased throughput
Lower cost per analysis
Typical Applications
Pharmaceutical and QC analysis
Hydrophobic and neutral compound separations
Method development and optimization
Routine reversed‑phase workflows
High‑efficiency UHPLC analysis
Important Usage Notes
Requires UHPLC instrumentation capable of high pressure
Use 0.2 µm filtration to prevent column fouling
Ideal for applications requiring more resolution than short columns can provide
Suitable for standard‑flow UHPLC systems