UHPLC Column, RP C18, 1.8um, 100A. 2.1mm ID x 50mm Length. Cogent Brand. 1 EA.

Additional Info:

The 68118‑05P‑2 Cogent RP C18 UHPLC Column is a high‑efficiency reversed‑phase column featuring 1.8 µm particles and fully end‑capped C18 bonding, delivering maximum efficiency, high resolution, and reliable retention for hydrophobic analytes.

This column is manufactured using high‑purity silica with traditional C18 (octadecylsilane) bonding, combined with double end‑capping, which:

  • Minimizes residual silanol interactions

  • Improves peak shape for polar and basic compounds

  • Enhances reproducibility and method robustness

The result is a dependable, “first‑choice” C18 column for both routine analysis and method development.

50 mm Length – Speed & UHPLC Throughput

  • Designed for short run times and rapid analysis

  • Lower backpressure compared to longer columns

  • Ideal for high‑throughput workflows and screening

  • Suitable for fast method development and LC‑MS applications

Flow Rate & System Requirements (2.1 mm ID, 1.8 µm)

Requires UHPLC system capability

  • Typical flow rate range: ~0.2–0.5 mL/min

  • Optimal starting range: ~0.3–0.4 mL/min

  • Requires:

    • UHPLC system capable of high pressure operation

    • Low‑volume detector (optimized for 2.1 mm ID)

    • Precise low‑flow pumping

⚠️ Due to 1.8 µm particles, this column generates higher backpressure and may not be compatible with standard HPLC systems.

✅ Sample preparation requirement: filter samples with a 0.2 µm syringe filter prior to injection to prevent clogging.

Why Choose RP C18 for UHPLC

High Efficiency & Resolution

  • Sub‑2 µm particles provide maximum plate count

  • Improves resolution compared to 3 µm and larger particles

  • Maintains separation quality even with shorter run times

Reliable Hydrophobic Retention

  • Ideal for hydrophobic and neutral compounds

  • Strong and predictable reversed‑phase behavior

Method Development Versatility

  • Widely applicable across industries

  • Excellent starting point for new methods

  • Easy method transfer to longer column formats

Cogent RP C18™ Advantages

Fully End‑Capped Surface

  • Minimizes secondary interactions

  • Improves peak symmetry

  • Better performance for basic analytes

High Purity Silica

  • Consistent and reproducible separations

  • Reduced variability batch‑to‑batch

Cost‑Efficient Operation

  • Reduced solvent consumption with 2.1 mm ID

  • Increased throughput

  • Lower cost per analysis

Typical Applications

  • LC‑MS analytical workflows

  • Pharmaceutical and QC analysis

  • Hydrophobic and neutral compound separations

  • Method development and optimization

  • High‑throughput UHPLC analysis

Important Usage Notes

  • Requires UHPLC system capable of high pressure

  • Use 0.2 µm filtration to protect column integrity

  • Ideal for fast, high‑efficiency separations

  • Commonly used with LC‑MS systems

 