UHPLC Column, RP C18, 1.8um, 100A. 4.6mm ID x 50mm Length. Cogent Brand. 1 EA.
Additional Info:
The 68118‑05P Cogent RP C18 UHPLC Column is a high‑efficiency reversed‑phase column featuring 1.8 µm particles and fully double end‑capped C18 bonding, providing maximum efficiency, strong retention, and highly reproducible separations.
Manufactured with high‑purity silica and traditional octadecylsilane (C18) bonding, this column is fully end‑capped to:
Minimize residual silanol activity
Improve peak shape—especially for polar and basic compounds
Deliver consistent and reliable chromatographic performance
This makes RP C18 the preferred “first‑choice” column for routine methods, method development, and high‑throughput environments.
50 mm Length – Speed & Throughput
Designed for fast separations and short run times
Lower analysis time compared to longer columns
Ideal for high‑throughput screening (HTS)
Efficient for rapid method development and optimization
Flow Rate & System Requirements (4.6 mm ID, 1.8 µm)
⚠️ Requires UHPLC system capability due to high backpressure
Typical flow rate range: ~1.0–2.0 mL/min
Optimal starting range: ~1.2–1.5 mL/min
Requires:
UHPLC system capable of high‑pressure operation
Standard flow detector compatible with 4.6 mm ID
Stable high‑flow pumping capability
✅ Sample preparation requirement: filter samples using a 0.2 µm syringe filter prior to injection to avoid clogging.
Why Choose RP C18 for UHPLC
Maximum Efficiency at High Speed
1.8 µm particles provide high plate counts and peak capacity
Maintains resolution while significantly reducing run times
Improves performance compared to 3 µm+ particle columns
Reliable Hydrophobic Retention
Strong, predictable retention for hydrophobic and neutral compounds
Ideal for routine analytical applications
Versatile Method Development Platform
Widely applicable across industries and analyte classes
Serves as a universal starting point for new methods
Easy scaling between column lengths and IDs
Cogent RP C18™ Advantages
Fully End‑Capped Surface
Minimizes secondary interactions
Improves peak symmetry
Provides better performance for basic analytes
High Purity Silica
Consistent column‑to‑column performance
Reduced variability and improved reproducibility
Cost‑Efficient Operation
Shorter run times = higher throughput
Reduced solvent waste vs longer columns
Lower overall operating cost per analysis
Typical Applications
High‑throughput analytical HPLC
Pharmaceutical analysis and QA/QC
Hydrophobic and neutral compound separations
Method development and optimization
Routine reversed‑phase workflows
Important Usage Notes
Requires UHPLC system (high pressure capable)
Use 0.2 µm filtration to protect column lifetime
Ideal for fast, high‑efficiency analytical workflows
Best suited for standard‑flow HPLC systems upgraded to UHPLC capability