HPLC Column, RP C18, 10um, 4.6mm ID x 250mm Length, 100A. Cogent Brand. 1 EA.
Additional Info:
The 68018‑25P Cogent RP C18 HPLC Column is designed for maximum separation performance and method compatibility, utilizing 10 µm particles and fully double end‑capped C18 bonding to provide reliable retention, excellent durability, and consistent chromatographic results.
Manufactured using high‑purity silica with traditional octadecylsilane (C18) bonding, this stationary phase provides:
Complete end‑capping to minimize silanol interactions
Improved peak symmetry for polar and basic analytes
Consistent and reproducible chromatography
This column is widely used as a USP L1 alternate and is especially valuable for legacy methods that specify longer column formats.
250 mm Length – Maximum Separation & Peak Capacity
Highest resolving power in the 4.6 mm RP C18 (10 µm) range
Maximizes peak capacity for highly complex mixtures
Ideal for closely related compounds and difficult separations
Provides extended retention for hydrophobic analytes
Best suited for final method validation and high‑purity separations
This format is selected when shorter columns cannot achieve the required separation performance.
4.6 mm ID – Standard Analytical Performance
Industry‑standard HPLC column dimension
Compatible with all conventional HPLC systems
Typical flow rate range: ~0.8–1.5 mL/min
Optimal starting range: ~1.0–1.2 mL/min
Provides:
Strong detector response
Reliable reproducibility
Easy method transfer across laboratories
Flow Rate & System Considerations (4.6 mm ID, 10 µm)
Suitable for standard HPLC systems
Supports higher flow rates and increased loading capacity
Well suited for:
Legacy analytical methods
Method validation workflows
Complex, extended separations
Why Choose RP C18 (10 µm)
Ideal for Legacy & Preparative Method Alignment
Commonly used in older validated methods still in use today
Maintains method conformity without revalidation
Suitable for analytical-to-preparative method scaling workflows
Reliable Hydrophobic Retention
Strong reversed‑phase retention for hydrophobic and neutral compounds
Excellent for long‑chain fatty acids
Provides greater retention than C8 phases
USP Method Compatibility
Suitable for USP L1 methods
Reliable alternate column for regulated environments
Supports method transfer and validation consistency
Cogent RP C18™ Advantages
Fully End‑Capped Surface
Minimizes secondary interactions
Improves peak symmetry
Enhances performance for basic analytes
High Purity Silica
Consistent chromatographic performance
Reduced variability between runs
Durable & Cost‑Efficient
Long column lifetime
Ideal for validated and repeat workflows
Reduced maintenance frequency
Typical Applications
Legacy USP L1 method replacement
Pharmaceutical QC and validation
Hydrophobic and neutral compound separations
Long‑chain fatty acids
Complex multi‑component mixtures
Regulatory and method transfer workflows
Important Usage Notes
Compatible with standard HPLC systems
Ideal for maximum separation and legacy method replication
Use when method fidelity and reproducibility are critical
Optimize conditions to balance run time and resolution