HPLC Column, RP C8 Octyl, 10um, 4.6mm ID x 100mm Length, 100A. Cogent Brand. 1 EA.
Additional Information:
Cogent RP C8 Octyl is a reversed-phase HPLC stationary phase manufactured using high-purity silica with traditional octyl (C8) silane bonding and complete double endcapping. The moderate hydrophobicity of the C8 ligand provides an excellent balance between retention and elution strength, making it suitable for a broad range of hydrophobic and neutral compounds. This stationary phase is commonly selected as an alternative for USP methods that specify L7 column classifications and is frequently used when reduced retention compared to C18 phases is preferred.
68008-10P is an analytical HPLC column with dimensions of 4.6 mm ID x 100 mm length, packed with 10 µm RP C8 Octyl particles featuring a 100 Å pore size. The 100 mm length provides a balance between analysis speed and chromatographic resolution, making it suitable for routine analytical methods, method development, and quality control applications. The 10 µm particle size provides lower operating backpressure while supporting higher flow rates than smaller particle columns.
This column is well suited for analysis of hydrophobic and neutral compounds, including long-chain fatty acids and related analytes. The C8 stationary phase delivers less retention than C18 columns, which can reduce run times while maintaining effective separation. Its balanced selectivity and robust performance make it a practical choice for routine laboratory testing, pharmaceutical analysis, and USP L7 applications.
Key Benefits
RP C8 Octyl stationary phase
Fully double endcapped chemistry
Traditional octyl (C8) bonded phase
Suitable alternative for USP L7 methods
Lower retention than C18 columns
10 µm particles for lower operating backpressure
Balanced speed and resolution with 100 mm length
High-purity silica support
Robust analytical performance
Suitable for routine analytical methods
Typical Applications
USP L7 methods
Long-chain fatty acid analysis
Hydrophobic compound analysis
Neutral compound analysis
Method development
Pharmaceutical analysis
Quality control testing
Routine laboratory testing
Raw material analysis
Reversed-phase HPLC separations
Specifications
Product Type: Analytical HPLC Column
Stationary Phase: RP C8 Octyl
Chromatography Mode: Reversed Phase
USP Classification: L7
Bonded Phase: Octyl (C8)
Endcapping: Fully Double Endcapped
Particle Size: 10 µm
Pore Size: 100 Å
Column Dimensions: 4.6 mm ID x 100 mm
Length: 100 mm
Typical Flow Rate: 1.0–2.0 mL/min
Brand: Cogent
Important Notes
Suitable as an alternative for USP L7 methods
Provides less retention than C18 stationary phases
Commonly used for long-chain fatty acid separations
Offers a balance of speed and resolving power
Compatible with conventional HPLC systems